Workflow Attributes
This overview includes the attributes of this object type and describes their functions and allowed values as well as indications as to how to modify them.
Predefined variables may be used in scripts, and script variables may be set to attributes retrieved via predefined variables.
General Page
Title
OBJECT_TITLE
Value: User-defined
Length: 255 characters
Access through: GET_ATT, :PUT_ATT (Pre-Process, Process), predefined variable
Active
OH_Inactive
Access through: Change Program
Created by
USER_CREATED
Value: Name of the User object
Length: Max. 200 characters
Access through: GET_ATT, predefined variable
DATE_CREATED
Value: Timestamp
Format: YYYY-MM-DD HH:MM:SS. If not available, 0000-00-00 00:00:00
Access through: GET_ATT
Modified by
USER_MODIFIED
Value: Name of the User object
Length: 200 characters
Access through: GET_ATT, predefined variable
DATE_MODIFIED
Value: Timestamp
Format: YYYY-MM-DD HH:MM:SS. If not available, 0000-00-00 00:00:00
Access through: GET_ATT
MODIFY_COUNT
Value: Number of object modifications
Access through:GET_ATT
Last Executed
LAST_USER
Value: Name of the User object
Length: 200 characters
Access through: GET_ATT, predefined variable
LAST_DATE
Value: Timestamp
Format: YYYY-MM-DD HH:MM:SS. If not available, 0000-00-00 00:00:00
Access through: GET_ATT, predefined variable
USAGE_COUNT
Value: Number of object usages
Access through: GET_ATT, predefined variable
Archive Key 1
ARCHIVE_KEY1
Value: User-defined
Length: 60 characters
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
Archive Key 2
ARCHIVE_KEY2
Value: User-defined
Length: 20 characters
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
Int. Account
INT_ACCOUNT, INT_ACC, K
Value: User-defined
Length:16 characters
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
Sync Page
Sync Object
SYNC_OBJECT
Value: Name of the Sync object
Length: 20 characters
Access via: Change Program
Attributes Page
Queue
QUEUE
Value: Name of the Queue
Length: Max. 200 characters
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
Child Queue
CHILD_QUEUE
Value: Name of the Queue on which the task in the Workflow runs
Length: Max. 200 characters
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
Job Group
GROUP
Value: Name of the Job Group
Length: Max. 200 characters. Leave it empty for an immediate start.
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
Automation Engine Priority
UC4_PRIORITY
Value: User-defined
Length: A value between 0 and 255
Access through: GET_ATT, :PUT_ATT, predefined variable
Time Zone
TIMEZONE
Value: User-defined
Length: Max. 8 characters
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
Generate Task at: Runtime
GEN_AT_RUNTIME
Value: Y / N
Access through: GET_ATT
Allow <x> simultaneous executions
MAX_PARALLEL_TASKS
Value: User-defined
Length: A value between 0 and 99999
Access through: GET_ATT, :PUT_ATT, predefined variable
Tasks running simultaneously: Else
MAX_PARALLEL_ELSE
Value: WAIT (wait until execution is possible) / ABEND (Notification terminates)
Access through: GET_ATT, :PUT_ATT
Automatically deactivate when finished
AUTO_DEACT
Value:
- NEVER
- ENDED_ERROR_FREE (in case of error-free processing, deactivate automatically)
- RESTART_ERROR_FREE (in case of an error-free restart, deactivate automatically)
- ALWAYS
Access through: GET_ATT, :PUT_ATT
Error-free status (for After an error-free restart)
AUTO_DEACT_ERROR_FREE
Value: Task status (System Return Codes of Executable Objects)
Length: Max. 20 characters
Access through: GET_ATT, :PUT_ATT
Time delay minutes (for Always)
AUTO_DEACT_DELAY
Value: User-defined
Length: A value between 0 and 99
Access through: GET_ATT, :PUT_ATT
Workflow/Logic Tabs
Task Name
Name of the task in the Workflow that should be replaced.
TASK_NAME
Value: Name of the object
Length:Max. 200 characters
Access through: Change Program
VARA Object Name
Variable object name for ForEach Workflows.
FE_SRC_NAME
Value: Name of the VARA object
Length:Max. 200 characters
Access through: Change Program, predefined variable
Runtime Page
Return code <=
MAX_RETCODE
Value: User-defined
Length: 10 characters
Access via: GET_ATT, :PUT_ATT (Pre-Process, Process)
Note: The status of the file transfer does not affect its return code. If, for any reason, a file transfer fails, the return code is still 0.
Process Page
Code on the Process Page
SCRIPT
Changes the code on the Process page
Access through: Change Program
Workflow Attributes Not on a Tab
Object Name
OBJECT_NAME
Value: User-defined
Length: Max. 200 characters
Access through: Change Program
AWI Mode
DCMODUS
Value: Y / N
Access through: GET_ATT
See also: