Administration Guide > Configuration > Structure of the Configuration Files > Utility for VMS

Utility for VMS

Structure of the INI File UCXBVXXC.INI

Section/Parameter Description
[GLOBAL]   

system=

The name of the AE system.

This entry must be identical to the entry in the INI file of the Automation Engine.

helplib=

The name of the message file.

language=

The language in which the logging is processed. Entries for primary and secondary language.

Allowed values: "E", "D", "F"
Default: "E,D" (Primary English, secondary German)

If there is no log in the primary language, a log in the secondary language is searched for.

logging=

The path and file name of the log file.

The characters xx in the file names are place holders. They stand for the two-digit abbreviation of the respective VMS version. See: Terminology.

The number signs serve as place holders for a series in numerical order. When starting the agent, the log files are renamed so that the most current log file is always the one with the number "00".

logcount=

The number of stored log files.

timeout=

The time in seconds during which the CallAPI waits for a response from AE. If this is exceeded, the CallAPI ends with a timeout error.

Default value: 60

With the parameter timeout=0 being used, the CallAPI waits (without time limit) until the Automation Engine acknowledges.

queue=

The specification of a particular Queue object in which the CallAPI should be executed.

This parameter overrides the setting API_QUEUEin the variable UC_CLIENT_SETTINGS.

trace

Trace designation.

Allowed values:
"0" (default) = Deactivate trace
"1" = Activate trace

If the trace parameter is set to 1, additional information is written to STDOUT

[USER] 

 

client=

Login specifications: Client.

Login data from this section is used when no login data is specified at service-program call

user=

Login specifications: Name of the user.

dept=

Login specifications: Department of the user.

pass=

Login specifications: Password (optional).

[CP_LIST]

The address of the communication processes in the AE system.

Allowed formats:
Port number=DNS Name
Port number=TCP/IP Address

Example of an INI File

[GLOBAL]
system=UC4
helplib=ucx.msl
language=E,D
logging = [-.temp]UCXCVxx.l##
logcount = 6
timeout=60
;queue=
trace=1


[USER]
client=
user=
dept=
pass=


[CP_LIST]
2217=uc4srv01
; 2218=uc4srv02

 

See also: