Administration Guide > Configuration > Settings in Variables > UC_UTILITY_ARCHIVE - Archiving Specifications

UC_UTILITY_ARCHIVE - Archiving Specifications

The variable contains specifications and information concerning the archive process.

Key

Value

AH

Specifications for archiving statistical data

Format: flag days

Flag1 - archive statistics (TRUE - yes, FALSE - no)
Days
- archive old statistics

ARCHIVSET

Number of archive runs that have been processed so far. This value is also used for the name of the archive folder.

FORMAT

Date format for the output of date and time indications in the archive files.

LASTAHRH

Last archiving date of statistics and reports in the format YYYYMMDD.

LASTMELD

Last archiving date of messages in the format YYYYMMDD.

MELD

Specifications for archive messages

Format: flag days1 days2

Flag - archive messages (TRUE - yes, FALSE - no)
Days1
- archive read messages older than specified here
Days2
- archive unread messages older than specified here

PATH

Archive folder

SIZE

Archive size in MB

SIZEAH
SIZEMELD
SIZERH
TIMEAH
TIMEMELD
TIMERH

Data size and duration of the last archiving run. These values serve as the basis for the forecast calculation of the next archiving run.

Description

The utility AE.DB automatically creates and updates the variable in the client.

Manual intervention is not required as all entries are automatically supplied with values and maintained by the utility.

 

See also:

Overview of all variables in Table Form
Variable

Archiving