 Default values have been specified for most parameters. They can be changed if required. Parameters that must be adjusted to your system environment are written in red letters.

Structure of the INI File x.xxx.UCXJB2?.INI

Section/Parameter Description
(GLOBAL)  

SYSTEM=

Name of the AE system.

This entry must comply with the entry in the Automation Engine's INI file.

NAME=

Name of the agent. 

The agent name is limited to 32 of the following characters: A-Z, 0-9, _, ., $, @, - and #.

The host name is used instead if this parameter remains undefined. Lowercase letters are converted to uppercase letters.

Hyphens ("-") are only allowed in agent names. They must not be used in the names of any other objects.
LOGGING= Name of the log file.

You can enter the user ID here. If the User ID has not been specified, the log file is written to the User ID under which the job has been executed.

The number signs serve as placeholders for a series in numerical order. When you start the agent, the log files are renamed so that the most current log file is always the one with the number "00".

LOGCOUNT= Number of stored log files.
LANGUAGE=

Language that should be used for the logging. You can specify a primary and a secondary language.

Allowed values: E, D, F
Default: "E,D" (primary English, secondary German)

If there is no message in the primary language, the system searches for a message in the secondary language.

LICENCE_CLASS= License class that corresponds to the acquired license and the hardware and software that is used.

Allowed values: "1" to "9"
"1" to "9" = Agent's license class

JOINREAD=

Parameter that determines the passwordA secret combination of characters for a Automation Engine user. in BS2000 if there is no password in the Login object.

Allowed values: "0" and "1" (default value)

"0" = Do not determine password.
"1" = Determine password.

USERID_TYPE=

Additional way for the OS to allow or reject access to certain users.

Allowed values: INCL, EXCL

"INCL" = Access must be granted for every single user specified in (USERID).
"EXCL" = Access is denied to the users that are specified in (USERID). All other users can start jobs.

ft_temp_file=

Creates temporary files in file transfers.

Allowed values: "yes" (default value) and "no"

"yes" - The file obtains a temporary name that is composed of the letter "T" and an alphabetic string that stems from the RunID. The new file transfer protocol additionally appends a file ID in order to obtain a unique file name because basically, only a RunID is provided.The file is renamed after it has successfully been transferred.
"no" - The agent assigns the final file name when the file transfer starts.

FileProcessingTimeout=

The time limit in second for the file search

The file search aborts when the specified time limit is reached.

No time limit applies when you either define the setting "0" (default) or "-1".

This parameter is relevant for FileSystem events and the script element GET_FILESYSTEM.

FileProcessingMaxDepth=

The maximum level of sub-directories for FileSystem events.

You use this setting in order to determine the extent to which the directory structure is included in your search for FileSystem event files. The search directory serves as the basis for the maximum sub-directory level.

By limiting the directory level, you can improve the performance of FileSystem events especially when their folder structure is deeply nested and includes numerous files.

Allowed values:
"0" (default) = There is no limitation.
"1" = The files are only searched in the search directory. Sub-directories are not included in this search.
"2" = With this setting being used, the search for files includes the search directory and one directory level below.
"3" = The search includes the directory plus two sub-directory levels.
etc.

This parameter is relevant for FileSystem events and the script element GET_FILESYSTEM.

(AUTHORIZATION)  
InitialPackage=

The name and the path of the file that includes the authentication package (company-key file).

This parameter must be specified if you use the authentication methods "Server" or "Server and Agent". Any attempt to log in fails if the company-key file cannot be found.

When the agent starts, it reads the company-key file and stores its information in the file that is specified in the parameter KeyStore=. The first file is deleted afterward.

KeyStore=

The name and the path of the file that includes the information of the authentication package (see parameter InitialPackage=).

If no file name and/or path is specified, the system uses the name (file ending *.kstr) or the path of the agent's INI file. If you define a file name, the ending *.kstr is not automatically appended.

The KeyStore file is created when the agent starts for the first time. You must not delete, rename or move it subsequently. Regardless of the authentication method that you use, any attempt to log in will fail if the agent cannot find this file when it starts. In this case, you must open the menu item "Renew transfer key" in the affected agent's System Overview.

(USERID)

Entry of authorized BS2000 users in the format:
User name
=START

Entry of unauthorized BS2000 users in the format:
User name
=NO_START

(VARIABLES) This section contains the agent variables with agent information and settings.

(TRACE)

 

FILE= Name of the trace file.

You can enter the user ID here. If it is not entered, the trace file is written to the User ID under which the job has been executed.

The number signs serve as placeholders for a series in numerical order. When you start a trace, the trace files will be renamed so that the most current trace file is always the one with the number "00".

TRCCOUNT= Number of stored trace files.
TCP/IP=
FILETRANSFER=
UCON=
RFC=
MEMORY=
Trace flags of the agent.

Allowed values: "0" (default value) to "9"

Trace flags should only be used in close cooperation with Automic Support.

(TCP/IP)  
PORT= Port number of the agent.
Other agents and the Job Messenger establish a connection with the agent by using this port number.

BINDADDR=

IP address or host name for the connection to the agent.

Use this parameter if the connection should be established via a particular IP address (for example, the computer has more than one network interface card).

Alternately, you can also specify the IP address or host name in PORT=

(Format: PORT=IP address:port or DNS name:port). Specifications made in BINDADDR= are then ignored.

BINDLOCAL=

Consideration of local host (127.0.0.1).

Use this parameter together with BINDADDR=.

Allowed values: "0" (default value), "1"

"0" - No listen socket is created.
"1" - An additional listen socket is created on the local host.

CONNECT=

Time interval in seconds during which the agent tries to establish a connection to the Automation Engines. Affects the connection attempt for a restart or after a lost connection.

Default value: 240 seconds

This parameter is only effective until the first successful logon to the AE system. Afterwards, the parameter RECONNECT_TIME can be used in the host characteristics.

REPORT=

Time interval in seconds in which the agent sends the logging to the Automation Engine.

Default value: 60 seconds

CONNWAIT=

Time interval in seconds during which the agent waits for a response from the communication partner (CP or another agent). If the time limit is exceeded, the connection to the communication partner will be terminated again.

Default value: 20 seconds

CP=

Address of the communication process in the AE system to which the agent should connect.

Allowed formats:
DNS Name:Port number
TCP/IP Address:Port number

MAXMSGSIZE=

Maximum length of messages (in bytes) that the agent accepts.

Default value: 500 000

(HOSTS)

Assignment of an agent's name to its address (DNS name or TCP/IP address) if it cannot directly be accessed through the address that is stored in the server. Specify several assignments line by line, there is no upper limit for the number of assignments.

In file transfers, the sending agent obtains the destination agent's internal address from the Automation Engine. The sending agent replaces this internal address by the external address that is defined here.

This setting is only required if you run file transfers with agents that cannot directly establish a TCP/IP connection between each other by using the address that they have received from the Server. This can happen if the agents that are involved in the file transfer are located on different networks or if a firewall is used.

 

(RFC)

 

LOGON= File transfer: Evaluation of the User ID from the "File Transfer Parameters" tab .

Allowed values: "0" (default value) and "1"

"0" = The User ID is not evaluated. The file transfer runs with the agent's rights. Note that AE cannot ensure full auditing ability when you use this function because theoretically you can specify any user - even an invalid user.

"1" = UserID is evaluated.
For this purpose the agent starts an additional Enter (RFC task) with the respective UserID.
This task only checks the access rights for the affected file. The FileTransfer itself runs on the agent and the access rights of its user. For this reason the agent as well needs access rights for the file in question.

PORT=  Port number that the RFC task uses to establish the connection to the agent.
TIMEOUT= Agent's maximum waiting time for the RFC task (seconds).
ENTERPAR= Additional parameters for the RFC task (see Enter command).

TASKTIMEOUT=

Time period in seconds after which an RFC task stops.

An RFC task that is started by an agent can handle multiple file-transfers orders. It ends if it does not receive a task for the time period that is defined here.

(CP_LIST)

List of communication processes.

This list is created when the agent starts and is extended when new communication processes are activated. You will find more detailed information about establishing a connectiond in the chapter Multi-Server Operation.

The communication process that is defined in the parameter cp= (section [TCP/IP]) is not included in the cp list.

Format:
Port number
=DNS name
or
Port number
=TCP/IP address

Example of an INI File

(GLOBAL)

SYSTEM=UC4

NAME=BS2000

LOGGING=$UC4.L.LOGG.UCXJBXX.##

LOGCOUNT=10

LANGUAGE=(E,D)

LICENCE_CLASS=6

JOINREAD=1

USERID_TYPE=EXCL

ft_temp_file=yes

 

 

(AUTHORIZATION)

InitialPackage=

KeyStore=

 

 

(USERID)

TSOS=NO_START

 

 

(VARIABLES)

UC_HOST_CODE=BS2000_INTERNATIONAL

UC_HOST_JCL_VAR=BS2000

UC_EX_PATH_BIN=$UC4.UCX24.LIB

UC_EX_PATH_TEMP=$UC4.TEMP.

UC_EX_PATH_JOBREPORT=$UC4.JOB.REPORT.

UC_EX_JOB_MD=*MOD(LIBRARY=$UC4.UCX24.LIB,ELEMENT=UCXJB24M,RUN-MODE=*ADVANCED)

 

 

(TRACE)

FILE=$UC4.L.TRACE.UCXJBXX.##

TRCCOUNT=10

TCP/IP=0

FILETRANSFER=0

UCON=0

RFC=0

 

 

(TCP/IP)

PORT=2300

CONNECT=120

REPORT=60

CONNWAIT=20

CP=PC01:2217

 

 

(HOSTS)

; <AE-NAME>=<DNS-NAME> OR

; <AE-NAME>=<IP-ADDR>

 

 

(RFC)

LOGON=0

PORT=2400

TIMEOUT=90

ENTERPAR=,JOB-PRIORITY=8,START=*STD,RESOURCES=*PAR(RUN-PRIORITY=248)

TASKTIMEOUT=900

 

 

(CP_LIST)