Script Statement: Sends an SNMP trap
:SEND_SNMP_TRAPTrap Code, Parameter, [Parameter], [Parameter]...
Syntax |
Description/Format |
---|---|
Trap Code |
Freely-definable code to which SNMP management can react |
Parameter |
Additional information that can be sent with the SNMP trap Use inverted commas for the client number (e.g. "1000") |
This script statement sends an SNMP trap with its specified parameters to a management system. It can only be used if all requirements for SNMP functionality have been implemented.
Up to 10 parameters can be set and sent. From these, a maximum of 5 strings and 5 numbers is allowed. The position of strings and numbers is pre-determined. Strings must come first, then the numbers follow. At least one string must be indicated.
Trap codes generated by AE and HP OpenView Integrator (trap codes: 10000 - 10010) cannot be used.
The first example shows a simple test. Several parameters are sent to the management system with the SNMP trap 50000.
:SEND_SNMP_TRAP 50000,"Text1","TEXT2","TEXT3","TEXT4","TEXT5",1,2,3,4,5
In the second example, the activation data is determined in a first step. Depending on whether activation is made directly or within a workflow, different traps are sent. Both traps consist of the trap code and a prepared string.
:SET &NAME# =
SYS_ACT_ME_NAME()
:SET &ID# =
SYS_ACT_ME_NR()
:SET &JPNAME# =
SYS_ACT_PARENT_NAME()
:SET &CLIENT# =
SYS_ACT_CLIENT()
!Trap type = Alarm
:SET &TYPE# =
4
!Importance of the event
:SET &SEV# =
4
:IF "&JPNAME#" = ""
: SEND_SNMP_TRAP 50001, "&CLIENT#","Error in task &NAME#
(&ID#)!",,,,&TYPE#,&SEV#
:ELSE
: SET &JPID# = SYS_ACT_PARENT_NR()
: SEND_SNMP_TRAP 50002, "&CLIENT#","Error in workflow
&JPNAME# (&JPID#) in the task &NAME# (&ID#m)!",,,,&TYPE#,&SEV#
:ENDIF
The third example shows how the retrieved activation data is assigned to the script statement in the form of individual parameters. Thus, activation data is available in the management system in individual values which facilitates any further processing.
:SET &NAME# =
SYS_ACT_ME_NAME()
:SET &ID# =
SYS_ACT_ME_NR()
:SET &JPNAME# =
SYS_ACT_PARENT_NAME()
:SET &CLIENT# =
SYS_ACT_CLIENT()
!Trap type = Alarm
:SET &TYPE# =
4
!Importance of the event
:SET &SEV# =
4
:IF &JPNAME# = ""
: SEND_SNMP_TRAP 50001,"&CLIENT#","&NAME#",,"Error in the task!",,&TYPE#,&SEV#,&ID#
:ELSE
: SET &JPID = SYS_ACT_PARENT_NR()
: SEND_SNMP_TRAP 50002,"&CLIENT#","&NAME#","&JPNAME#","Error in the workflow!",,&TYPE#,&SEV#,&ID#,&JPID#
:ENDIF
If &ID# and/or &JPID# should be sent as numbers rather than as strings, they can only be assigned after the fifth parameter. Commas must be used in place of unused parameters which are meant for strings.