Section/Parameter | Description |
---|---|
(GLOBAL) | |
system= |
The name of the AE system. This entry must be identical to the entry in the INI file of theAutomation Engine |
helplib= |
The name of the message file. |
language= |
The language in which the logging is processed. Entries for primary and secondary language. Allowed values: "E", "D",
"F" If there is no log in the primary language, a log in the secondary language is searched for. |
timeout= |
The time in seconds during which the CallAPI waits for a response from AE. If this is exceeded, the CallAPI ends with a timeout error. Default value: 60 |
trace |
Trace designation. Allowed values:
If the trace parameter is set to 1, additional information is written to STDOUT |
(USER) |
|
client= |
Login specifications: Client Login data from this section is used when no login data is specified at service-program call |
user= |
Login specifications: The name of the user. |
dept= |
Login specifications: The departmentDepartment name to which the Automation Engine user belongs. of the user. |
pass= |
Login specifications: Password (optional) |
(CP_LIST) |
The address of the communication processes in the AE system Allowed formats: |
(GLOBAL)
system=UC4
helplib=DD:PRD2.UC4(UCX.MSL)
language=(E,D)
timeout=60
trace=1
(USER)
client=
user=
dept=
pass=
(CP_LIST)
2217=uc4srv01
; 2218=uc4srv02
See also:
Notes for Configuration-File Adjustments