Section/Parameter | Description |
---|---|
[GLOBAL] | |
system= |
The name of the AE system. This entry must be identical to the entry in the INI file of the Automation Engine. |
helplib= |
The name of the message file, |
language= |
Language in which the logging is executed. Entries for primary and secondary language. Allowed values: "E", "D",
"F" If there is no log in the primary language, a log in the secondary language is searched for. |
logging= |
The name of the log file. The number signs serve as place holders for a series in numerical order. When starting the agent, the log files are renamed so that the most current log file is always the one with the number "00". |
logcount= |
The number of stored log files. |
timeout= |
The time in seconds during which the CallAPI waits for a response from AE. If this is exceeded, the CallAPI ends with a timeout error. Default value: 60 |
TRACE |
Trace designation. Allowed values:
If the trace parameter is set to 1, additional information is written to STDOUT |
[USER] |
|
client= |
Login specifications: Client. Login data from this section is used when no login data is specified at service-program call |
user= |
Login specifications: Name of the user. |
dept= |
Login specifications: Department of the user. |
pass= |
Login specifications: Password (optional). |
[CP_LIST] |
The address of the communication processes in the AE system. Allowed formats: |
[GLOBAL]
system=UC4
helplib=UCMSL
language=E,D
logging=$data01.uc4.LOGA##
logcount=10
timeout=60
TRACE=1
[USER]
client=
user=
dept=
pass=
[CP_LIST]
2217=uc4srv01
; 2218=uc4srv02
See also:
Notes for Configuration-File Adjustments