Administration Guide > Configuration > Settings in Variables > UC_EX_HOSTCHAR - Assigning Agents to Host Characteristics

UC_EX_HOSTCHAR - Assigning Agents to Host Characteristics

This variable can be used to assign agents to particular host characteristics.

Key

Value

New start required

Name of the agent

Name part of the variable which contains host characteristics
Maximum 188 figures

Default value: DEFAULT

Agent

Description

This variable is provided in client 0000. Its setting applies for the entire AE system and can only be changed from in client "0000".

It contains the appropriate host characteristics for every agent in the AE system. By default, host characteristics are retrieved from the variable UC_HOSTCHAR_DEFAULT which is found in the system client 0000. Duplicate this variable if different settings are required for particular hosts. The name of the new variable must be composed of UC_HOSTCHAR_ and a user-defined suffix.

When an agent logs on to the Automation Engine, the variable UC_EX_HOSTCHAR is scanned for an entry for this host.

Example

The agent UNIX25 uses the standard host characteristic UC_HOSTCHAR_DEFAULT and the agent WIN01 uses the newly created  AE variable UC_HOSTCHAR_WIN.

Key

Value

UNIX25

DEFAULT

WIN01

WIN

 

See also:

Overview of all variables in table form
Variable