Default values have been specified for most parameters. They can be changed if required. Parameters that must be adjusted to your system environment are written in red letters.
Section/Parameter | Description |
---|---|
[GLOBAL] | |
name= |
Name of the agent. The agent name is limited to 32 of the following characters: A-Z, 0-9, _, ., $, @, - and #. The host name is used instead if this parameter remains undefined. Lowercase letters are converted to uppercase letters. Hyphens ("-") are only allowed in agent names. They must not be used in the names of any other objects. |
system= | Name of the AE system. This entry must comply with the entry in the INI file of the Automation Engine. |
language= |
Language that should be used for the logging. You can specify a primary and a secondary language. Allowed values: "E", "D",
"F" If there is no message in the primary language, the system searches for a message in the secondary language. |
logging= | Path and file name of the log file.
The xx characters in the file name are placeholders. They stand for the two-character abbreviation of the respective Windows version. See:Terminology. The number signs serve as placeholders for a series in numerical order. When you start the agent, the log files are renamed so that the most current log file is always the one with the number "00". |
logcount= | Number of stored log files. |
helplib= | Name of the message file. |
helpcache= | Availability of the messages and language dependant strings.
Allowed values: ALL (default value),
NONE, CONTROLS |
WRITE= |
You can use this parameter to specify the type of message transfer (such as lines in reports). Note that individual transfers that include thousands of lines will negatively affect the performance of the Automation Engine). Allowed values: "0" (default value), "1" "0" - Messages are sent separately. |
WRITE_TIME= |
Interval in seconds during which blocks are sent. |
[AUTHORIZATION] | |
InitialPackage= |
The name and the path of the file that includes the authentication package (company-key file). This parameter must be specified if you use the authentication methods "Server" or "Server and Agent". Any attempt to log in fails if the company-key file cannot be found. When the agent starts, it reads the company-key file and stores its information in the file that is specified in the parameter KeyStore=. The first file is deleted afterward. |
KeyStore= |
The name and the path of the file that includes the information of the authentication package (see parameter InitialPackage=). If no file name and/or path is specified, the system uses the name (file ending *.kstr) or the path of the agent's INI file. If you define a file name, the ending *.kstr is not automatically appended. The KeyStore file is created when the agent starts for the first time. You must not delete, rename or move it subsequently. Regardless of the authentication method that you use, any attempt to log in will fail if the agent cannot find this file when it starts. In this case, you must open the menu item "Renew transfer key" in the affected agent's System Overview. |
[STATUS_CHECK] |
|
time= |
This is the system-internal timer cycle that checks the status of a job compared to SAP. Default value: 1 second The agent's internal job table is checked in this interval. Whether the job's status is checked depends on its runtime. The job is checked while it is running at constantly increasing time intervals (the "time" value is doubled). However, these intervals never exceed the value that is specified for the agent in the parameter JOB_CHECKINTERVAL in the host characteristics. For example: time=1, JOB_CHECKINTERVAL=60 The job table is checked each second. Status check after: 1s, 2s, 4s,..., 60s, 60s.... |
[TRACE] |
|
file= |
Path and file name of the trace file. The xx characters in the file name are placeholders. They stand for the two-digit abbreviation of the particular Windows version. See: Terminology The number signs serve as placeholders for a series in numerical order. When you start a trace, the trace files are renamed so that the most current trace file is always the one with the number "00" |
trccount= | Number of stored trace files. |
tcp/ip= filetransfer= mail= |
Trace flags for TCP/IP communication of the agent.
Allowed values: "0" (default value) to "9" Trace flags must only be used in close cooperation with Automic Support. |
[TCP/IP] | |
port= | Port number of the agent. Other agents and the Job Messenger establish connection with the agent via this port number. |
bindaddr= |
IP address or host name for Server-process connection. You can use this parameter when the connection should be established via a particular IP address (e.g. the computer has more than one network interface card). Alternately, you can also specify the IP address or host name in port=. (Format: port=IP address:port or DNS name:port). Specifications made in bindaddr= are then ignored. |
bindlocal= |
Consideration of local host (127.0.0.1). Use this parameter together with bindaddr=. Allowed values: "0" (default value), "1" "0" - No listen socket is created. |
connect= |
Time interval in seconds in which the agent triets to establish connection to the Automation Engines. This affects the connection setup for a restart or after a lost connection. Default value: 60 seconds This parameter is only effective until the first successful logon to the AE system. Afterwards, you can use the parameter RECONNECT_TIME in the host characteristics. |
report= |
Time interval in seconds in which the agent sends the logging to the Automation Engine. Default value: 60 seconds |
SendBufferSize= |
Size of the TCP/IP input buffer for messages that should be sent. |
RecvBufferSize= |
Size of the TCP/IP input buffer for messages that should be received. |
cp= |
Address of the communication process in the AE system to which the agent should connect. Allowed formats: |
connwait= |
Time interval in seconds during which the agent waits for a response from the communication partner (a CP or another agent). If the time limit is exceeded, the connection to the communication partner will be terminated again. Default value: 20 seconds |
[VARIABLES] |
This section contains agent variables that include agent settings and information. |
[SIEBEL] |
|
DELIMITER= |
Separator for the log-file content. Siebel log files are structured in tables. You can use this parameter to define a column separator (such as *). |
repeat_check= |
The number of repeated status checks if the Siebel system does not return the relevant job. Only then, the job is deemed to be vanished (ENDED_VANISHED). Background information: It can occur that a "list task" command does not list the jobs that are active in the Siebel system. Therefore, these jobs obtains the status ENDED_VANISHED. Nevertheless, the affected jobs are still running in the Siebel system. To avoid this problem, the agent check the states repeatedly according to the definitions you set in this parameter. Allowed values: 0 to 2147483647 |
report_repeat_check= |
Logging if the job could not be found in the Siebel system. Allowed values: "0" and "1" "1" - Each of the agent's repeated status checks causes a message that is written to the job report. |
[CP_LIST] |
List of communication processes. This list is created when the agent starts and extended when new communication processes are activated. You will find more detailed information about establishing a connection in the chapter Multi-Server Operation. The communication process that has been defined in the parameter cp= (section [TCP/IP]) is not included in the cp list. Format: |
[GLOBAL]
name=SI8
system=UC4
language=(D,E)
logging=..\temp\siebel_log##.txt
logcount=10
helplib=uc.msl
helpcache=all
WRITE=1
WRITE_TIME=120
[AUTHORIZATION]
InitialPackage=
KeyStore=
[STATUS_CHECK]
time=1
[TRACE]
file=siebel_trc##.txt
trccount=10
tcp/ip=4
filetransfer=0
mail=0
[TCP/IP]
port=2509
connect=30
report=60
SendBufferSize=32768
RecvBufferSize=32768
cp=PC01:2217
connwait=120
[VARIABLES]
UC_HOST_CODE=UC_CODE
UC_HOST_JCL_VAR=SIEBEL
UC_EX_PATH_BIN=.
UC_EX_PATH_TEMP=..\temp\
UC_EX_PATH_JOBREPORT=..\temp\
UC_SIEBEL_SRVRMGR=C:\siebel\srvrmgr.exe
UC_SIEBEL_LOGPATH=C:\siebel\siebelLOGS\
[SIEBEL]
DELIMITER=*
[CP_LIST]
2218=PC01
See also: