The following table lists the attributes that apply to File System event objects and describes their functions, allowed values and ways of modification. Fields in tables are ordered as they are displayed in the UserInterface.
Note that hosts can only be changed within a platform (such as WIN01 to WIN02). Script processing will abort if an attempt is made to change a BS2000 host to a UNIX host.
Predefined variables may be used in scripts, and script variables may be set to attributes retrieved via predefined variables.
Field |
Attribute |
Value |
Access Via: |
---|---|---|---|
Host |
HOST |
The name of an agent, |
GET_ATT, |
Path |
EVENT_FILE_PATH |
User-defined, |
GET_ATT, |
Include sub- directories | EVENT_INCLUDE_SUB_DIR | "Y" - Yes, "N" - No |
GET_ATT, :PUT_ATT |
Event - Check |
EVENT_CHECK_METHOD1 |
"FILE_SIZE" - file size |
GET_ATT, |
EVENT_COMP_TYPE |
">" - Greater than |
GET_ATT, |
|
EVENT_COMP_VALUE |
User-defined, |
GET_ATT, |
|
EVENT_COMP_UNIT |
"HOST_SPECIFIC" - Complies with the settings in the target system, |
GET_ATT, |
|
Event - and | EVENT_CHECK_METHOD2 |
"FILE_CHANGED" - Last modification time of a size Setting one of these two values has the effect that the following attributes are automatically filled with the suitable values:
EVENT_REPEAT = "F" |
GET_ATT, :PUT_ATT |
Event- within | EVENT_CHECK_WITHIN | HHHHMMSS - period | GET_ATT, :PUT_ATT |
Event- Consider all Files | EVENT_CONSIDER_ALL | "Y" - Yes, "N" - No |
GET_ATT, :PUT_ATT |
Check |
EVENT_REPEAT |
"R" - Repeatedly |
GET_ATT, |
Timer control |
EVENT_TIME |
MMMM - Minutes in interval |
GET_ATT, |
First check |
EVENT_FIRST_EXEC |
"N" - After the time has expired |
GET_ATT, |
Start after check time |
EVENT_START_AFTER_SCH |
"N" - Do not run |
GET_ATT, |
See also:
Event
Attributes
GET_ATT function
:PUT_ATT statement
AE DB Change