ScriptEigener Objekttyp in der Automation Engine Function: Supplies the text of the previous restart point as defined in the script.
Syntax
SYS_LAST_RESTART_TEXT()
Return codes |
---|
Text of the restart point that has last been passed. |
Comments
Restart points are set using the script element :RESTART.
Examples
In the following example, files are copied from an AE directory. "Program directory" is written in the activation report as it is the restart text referring to the previous restart point.
:RESTART BIN, "Program directory"
COPY C:\AEG\BIN\*.* C:\BACKUP\AEG\BIN\*.* /Y
:INC DOS.ERRORLEVEL
:SET &RET# = SYS_LAST_RESTART_TEXT()
:PRINT "Last restart point: &RET#"
:RESTART DB,
"Database directory"
XCOPY C:\AEG\DB\*.* C:\BACKUP\AEG\DB\*.* /E /Y
:INC DOS.ERRORLEVEL
The second example supplies the result "Restart Point BIN" as no text was specified for the restart point.
:RESTART BIN
:SET &RET# = SYS_LAST_RESTART_TEXT()
:PRINT &RET#
See also:
Script element | Description |
---|---|
This is used to set restart points in an executable object. | |
SYS_LAST_RESTART_POINT | Supplies the name of the previous restart point in the script. |
Script Elements - Activation Data
About Scripts
Script Elements - Alphabetical Listing
Script Elements - Ordered by function