ONE Installer - Best Practices
The ONE Installer installs Automic Automation and its dependencies from a single executable.
When to Use the ONE Installer
You can use the ONE Installer for proof of concepts, testing purposes, and non-production use only.
Important! Do not use the ONE Installer in a production environment.
Prerequisites
The ONE Installer depends on the system requirements detailed in the Installation Requirements section of the ONE Installer, see ONE Installer - Single-Box Installation. The server should not have AEor AWI installed. Additionally, the following is required to use the ONE Installer:
- Ports – The following ports must be available:
- 80 (for Internet Information Services)
- 2217-2221 (for Communication Process connections)
- 2270-2279 (for Work Process connections)
- 8080 (AWI)
- 8871 (Service Manager)
- 8090 (Analytics Backend)
- 5434 (Analytics Datastore)
- 8081 (Analytics Rule Engine/Event Engine)
- 9092 and 2181 (Analytics Streaming Platform)
- Relevant database driver (SQL Server Native Client 11 for Microsoft)
- JDBC driver for the desired database
- Empty AE database and users, see Preparing for the Manual Installation
- Ensure that the database server and client have TCP/IP connections enabled
- Administrative rights to execute the installer