The table shown below describes the XML-file structure of a Notification object and explains the individual elements.
Element |
Description |
---|---|
uc-export |
Main element of the export file clientvers = Automation Engine version in which the export file was created |
CALL |
client = The client. |
XHEADER |
XHEADER in executable objects see object types The attribute "state" is used system-internally and must not be changed. |
Title |
User-defined, max. 255 characters |
Created |
Format: |
Modified |
Format:
|
LastUsed |
Format: |
ArchiveKey1 |
User-defined, Attribute: ARCHIVE_KEY1 |
ArchiveKey2 |
User-defined, Attribute: ARCHIVE_KEY2 |
ExtRepDef |
ExtRepDef:
Default value (UC_CLIENT_SETTINGS) Allowed values: "1" (selected) and "0" (not selected) Only one of the three options can be selected. |
SYNCREF |
only for executable objects The attribute "state" is used system-internally and must not be changed. |
Syncs |
Attributes per Sync object definition (row): Abend = Action when the task is canceled Up to 40 Sync object definitions are allowed. |
ATTR_CALL |
In all objects except for User, UserGroup, Cockpit, CodeTable, Documentation, Include and Login (ATTR_object type) objects. The attribute "state" is used system-internally and must not be changed. |
StartType |
Name of a group, Attribute: START_TYPE |
IntAccount |
User-defined, Attribute: INT_ACCOUNT, INT_ACC or K |
MaxParallel2 |
Maximal number of tasks running parallel User-defined, Attribute: MAX_PARALLEL_TASKS |
MpElse1 |
Maximal number of tasks running parallel - Else MpElse1: wait Allowed values: "1" (selected) and "0" (not selected) Attribute: MAX_PARALLEL_ELSE |
UC4Priority |
User-defined, Attribute: UC4_PRIORITY |
Priority |
Allowed values: "1|high", "2|normal", "3|low" Attribute: CO_PRIORITY |
Type |
Allowed values: "0|request", "1|message", "2|alert", 3|E-Mail Attribute: CO_TYPE |
ActAtRun |
Allowed values: "1" (selected) and "0" (not selected) Attribute: GEN_AT_RUNTIME |
TZ |
Name of a TimeZone object, Attribute: TIMEZONE |
EscTime |
Time in minutes Attribute: CO_RISING_TIME |
Object |
Name of a Notification object Attribute: CO_RISING_NAME |
AutoDeact |
Allowed values: "1" (selected) and "0" (not selected) |
External1 |
Allowed values: "1" (selected) and "0" (not selected) Attribute: CO_SNMP |
External2 |
Allowed values: "1" (selected) and "0" (not selected) Attribute: CO_EMAIL |
NOTIFICATION |
in all Notification objects The attribute "state" is used system-internally and must not be changed. |
Subject |
User defined, |
Text |
User-defined, Attribute: CALL_TEXT |
AttachReports |
RunID of an object or name of an object variable which contains a RunID, |
AttachFile |
Path and file name of the file to be sent, |
CALL |
in Notification objects The attribute "state" is used system-internally and must not be changed. |
Cond |
Attributes per operator definition (row): CaleKeyName = Calendar keyword Attribute: OPERATOR |
RUNTIME |
only for executable objects The attribute "state" is used system-internally and must not be changed. |
MaxRetCode |
Value ranging between "0" and "2147483647" Attribute: MAX_RETCODE |
FcstStatus |
Format: "system return code|status text" see also return codes |
Ert |
Time in seconds Value ranging between "0" and "35999999" |
ErtMethodDef |
ErtMethodDef: Default value (UC_CLIENT_SETTINGS) Allowed values: "1" (selected) and "0" (not selected) Only one of the three options can be selected. |
ErtFix |
Fixed value for ERT calculation This value is part of the fixed value calculation method (ErtMethodFix). Time in seconds Value ranging between "0" and "35999999" |
ErtDynMethod |
These values are part of the dynamic calculation method. ErtDynMethod: Method ErtCnt: Runs ErtCorr: Percentage of runs ErtIgn: Deviation in percent ErtIgnFlg: Consider deviation ErtMinCnt: Minimum runs |
MrtMethodNone |
Monitoring the maximum runtime (MRT) MrtMethodNone: None Allowed values: "1" (selected) and "0" (not selected) Only one of the four options can be selected. |
MrtFix |
Fixed value for MRT monitoring This value is part of the fixed value monitoring method (MrtMethodFix). Time in seconds Value ranging between "0" and "35999999" |
MrtErt |
This value is part of the monitoring method Ert + (MrtMethodErt). Value ranging between "0" and "999" |
MrtDays |
These values are part of the monitoring method Curr. Date + (MrtMethodDate). MrtDays: Days MrtTime: Time MrtTZ: TimeZone |
SrtMethodNone |
Monitoring the minimum runtime (SRT) SrtMethodNone: None Allowed values: "1" (selected) and "0" (not selected) Only one of the three options can be selected. |
SrtFix |
Fixed value for SRT monitoring This value is part of the monitoring method fixed value (SrtMethodFix). Time in seconds Value ranging between "0" and "35999999" |
SrtErt |
This value is part of the monitoring method ERT - (SrtMethodErt). Value ranging between "0" and "999" |
MrtCancel |
Cancel/quit (only for MRT monitoring) Allowed values: "1" (selected) and "0" (not selected) |
MrtExecute |
MrtExecute: Allowed values: "1" (selected) and "0" (not selected) MrtExecuteObj: |
DYNVALUES |
in all executable object except for the Cockpit (CPIT) The attribute "state" is used system-internally and must not be changed. |
dyntree |
List of object variables and PromptSet assignments Definition (node) of the "Values" area and of each PromptSet assignment with the following attributes: content = Content available. Allowed values: "0" (no), "1" (yes)
Structure of the "Values" area (node id="VALUE") Values: Table with object variables Mode: Inherit from parent
Structure of PromptSet assignment definitions (node id="PRPTS"): PROMPTSET definition with the following attributes: PROMPTBOX with the PromptSet element definitions and their values: |
SCRIPT |
only in executable objects Exception: In Event objects, it is the "!Process" tab. The attribute "state" is used system-internally and must not be changed. |
MSCRI |
Content of the Process tab |
DOCU_Title |
in all objects (DOCU_Title) The attribute "state" is used system-internally and must not be changed. The attribute "type" shows the type of documentation: text = normal documentation |
DOC |
Content of the Documentation tab Depending on the documentation type, the CDATA section contains the text or the XML structure. |
See also:
Export file of a Notification
XML-File Structure for Imports and Exports