Administration Guide > Utilities > AE Revision Report > Creating Revision Reports

Creating Revision Reports

The utility AE DB Revision Report is called via the command line. Its complexity and content can be defined with parameters.

The following syntax should be applied:

The order of the parameters is freely selectable.

The line shown below serves as an example. All starting times and runtime modifications of client 3 which take place between 01.04. 20:00 and 02.04. 06:30 are output to the file C:\revision\report01.txt.

UCYBDBRR -B -C0003 -FSTART,RUN_MOD -OC:\revision\report01.txt -D120050401200000 -D220050402063000

All parameters except for -B and -C are optional. Hence, particular default values are used for the non-specified parameters in program calls. A list of these values including their descriptions is available in the document Start parameters.

Depending on the situation that has occurred, this utility supplies a particular return code when the process has finished.

Return code

Message number

Description

0

-

The utility has successfully ended processing.

1

U0036139

Error occurred when loading INI-file settings

2

U0036138

Error: not possible to allocate memory for PCX

3

U0021004

Cannot find INI file

4

U5005000

No batch mode - please use parameter -B!

5

U5005001

No client has been defined!

6

U0003301

Could not allocate memory

7

U5005008

Processing was canceled. The output file cannot be opened.

8

U0036134

Error: cannot connect to AE source databaseA database is an organized collection of data including relevant data structures.

9

U5005005

Processing was canceled. The date definition is either invalid or does not have the correct format (YYYYMMDDhhmmss).

10 U5005012 Processing was canceled. Versioning is in progress in client '&01'. Waiting for its end is not possible because the Automation Engine is not active.

 

See also:

Revision Report
Monitored Areas