Export File StructureThe table shown below describes the XML file structure of a RemoteTaskManager object and explains the individual elements.
| 
                     Element  | 
                
                     Description  | 
            
|---|---|
| 
                     uc-export  | 
                
                     Main element of the export file clientvers = Automation Engine version in which the export file was created  | 
            
| 
                     JOBQ  | 
                
                    
                     client = The client.  | 
            
| 
                     XHEADER  | 
                
                    
                     XHEADER in executable objects see object types The attribute "state" is used system-internally and must not be changed.  | 
            
| 
                     Title  | 
                
                    
                     User-defined, max. 255 characters  | 
            
| 
                     Created  | 
                
                    
                     Format:   | 
            
| 
                     Modified  | 
                
                    
                     Format:
  | 
            
| 
                     LastUsed  | 
                
                    
                     Format:   | 
            
| 
                     ArchiveKey1  | 
                
                    
                     User-defined, Attribute: ARCHIVE_KEY1  | 
            
| 
                     ArchiveKey2  | 
                
                    
                     User-defined, Attribute: ARCHIVE_KEY2  | 
            
| 
                     ExtRepDef  | 
                
                    
                     ExtRepDef: 
 Default value (UC_CLIENT_SETTINGS) Allowed values: "1" (selected) and "0" (not selected) Only one of the three options can be selected.  | 
            
| 
                     SYNCREF  | 
                
                    
                     only for executable objects The attribute "state" is used system-internally and must not be changed.  | 
            
| 
                     Syncs  | 
                
                    
                     Attributes per Sync object definition (row): Abend = Action when the task is canceled Up to 40 Sync object definitions are allowed.  | 
            
| 
                     ATTR_JOBQ  | 
                
                    
                     In all objects except for User, UserGroup, Cockpit, CodeTable, Documentation, Include and Login (ATTR_Object type) objects. The attribute "state" is used system-internally and must not be changed.  | 
            
| 
                     HostDst  | 
                
                    
                     HostDst: Name of the agent HostAttrType: Name of the platform  | 
            
| 
                     MaxParallel  | 
                
                     Maximal number of tasks running parallel Value ranging between "1" and "999" Attribute: GR_MAX_PAR_JOBS  | 
            
| 
                     IntAccount  | 
                
                    
                     User-defined, Attribute: INT_ACCOUNT, INT_ACC or K  | 
            
| 
                     StartJobs  | 
                
                    
                     Start jobs: Start jobs Output: Transfer job reports to DB AutoTerm: Terminate Queue automatically. Allowed values: "1" (selected) 
 and "0" (not selected)  | 
            
| 
                     ReplChildren0  | 
                
                    
                     ReplChildren0: Flat Allowed values: "1" (selected) and "0" (not selected) Only one of the three options can be selected.  | 
            
| 
                     ActAtRun  | 
                
                    
                     Allowed values: "1" (selected) and "0" (not selected) Attribute: GEN_AT_RUNTIME  | 
            
| 
                     Consumption  | 
                
                    
                     User-defined,  Attribute: RESOURCE_CONSUMPTION  | 
            
| 
                     AEPriority  | 
                
                    
                     User-defined,  Attribute: UC4_PRIORITY  | 
            
| 
                     TZ  | 
                
                    
                     Name of a TimeZone object, Attribute: TIMEZONE  | 
            
| 
                     RMaxOK  | 
                
                     Result evaluation of the individual tasks in Workflow, RemoteTaskManager and Schedule objects Rwhen: OK status RExecute: Else  | 
            
| 
                     JOBQ  | 
                
                    
                     in RemoteTaskManager objects The attribute "state" is used system-internally and must not be changed.  | 
            
| 
                     QmFilters  | 
                
                     Filter of the RemoteTaskManager The attributes "HOSTAttrType", "QTypeMsgNr", "Text", "MaxLen", "MaxValue", "MinValue", "MsgNr", "Name", "OR" and "Type" are used system-internally and must not be changed.  | 
            
| 
                     operator  | 
                
                    
                     The attributes "OP" and "text" are used system-internally and must not be changed. Value: Value of the particular filter specification (text, number or timestamp in the format YYYY-MM-DDTHH:MM:SS) Filter specifications are available in the element "filter" of the attribute "name".  | 
            
| 
                     RUNTIME  | 
                
                    
                     only for executable objects The attribute "state" is used system-internally and must not be changed.  | 
            
| 
                     MaxRetCode  | 
                
                    
                     Value ranging between "0" and "2147483647" Attribute: MAX_RETCODE  | 
            
| 
                     FcstStatus  | 
                
                    
                     Format: "system return code|status text" see also return codes  | 
            
| 
                     Ert  | 
                
                    
                     Time in seconds Value ranging between "0" and "35999999"  | 
            
| 
                     ErtMethodDef  | 
                
                    
                     ErtMethodDef: Default value (UC_CLIENT_SETTINGS) Allowed values: "1" (selected) and "0" (not selected) Only one of the three options can be selected.  | 
            
| 
                     ErtFix  | 
                
                     Fixed value for ERT calculation This value is part of the fixed value calculation method (ErtMethodFix). Time in seconds Value ranging between "0" and "35999999"  | 
            
| 
                     ErtDynMethod  | 
                
                    
                     These values are part of the dynamic calculation method. ErtDynMethod: Method ErtCnt: Runs ErtCorr: Percentage of runs ErtIgn: Deviation in percent ErtIgnFlg: Consider deviation ErtMinCnt: Minimum runs  | 
            
| 
                     MrtMethodNone  | 
                
                     Monitoring the maximum runtime (MRT) MrtMethodNone: None Allowed values: "1" (selected) and "0" (not selected) Only one of the four options can be selected.  | 
            
| 
                     MrtFix  | 
                
                     Fixed value for MRT monitoring This value is part of the fixed value monitoring method (MrtMethodFix). Time in seconds Value ranging between "0" and "35999999"  | 
            
| 
                     MrtErt  | 
                
                    
                     This value is part of the monitoring method Ert + (MrtMethodErt). Value ranging between "0" and "999"  | 
            
| 
                     MrtDays  | 
                
                    
                     These values are part of the monitoring method Curr. Date + (MrtMethodDate). MrtDays: Days MrtTime: Time MrtTZ: TimeZone  | 
            
| 
                     SrtMethodNone  | 
                
                     Monitoring the minimum runtime (SRT) SrtMethodNone: None Allowed values: "1" (selected) and "0" (not selected) Only one of the three options can be selected.  | 
            
| 
                     SrtFix  | 
                
                     Fixed value for SRT monitoring This value is part of the monitoring method fixed value (SrtMethodFix). Time in seconds Value ranging between "0" and "35999999"  | 
            
| 
                     SrtErt  | 
                
                    
                     This value is part of the monitoring method ERT - (SrtMethodErt). Value ranging between "0" and "999"  | 
            
| 
                     MrtCancel  | 
                
                    
                     Cancel/quit (only for MRT monitoring) Allowed values: "1" (selected) and "0" (not selected)  | 
            
| 
                     MrtExecute  | 
                
                    
                     MrtExecute:  Allowed values: "1" (selected) and "0" (not selected) MrtExecuteObj:  | 
            
| VALUE | 
                    
                     in all executable object except for the Cockpit (CPIT) The attribute "state" is used system-internally and must not be changed.  | 
            
| Values | 
                    
                     Attributes per object-variable definition (row): Name = Name of the object variable (max. 32 characters) The number of object variables is not limited.  | 
            
| 
                     SCRIPT  | 
                
                    
                     only in executable objects Exception: In Event objects, it is the "!Process" tab. The attribute "state" is used system-internally and must not be changed.  | 
            
| 
                     MSCRI  | 
                
                     Content of the Process tab  | 
            
| 
                     POST_SCRIPT  | 
                
                    
                     only in jobs The attribute "state" is used system-internally and must not be changed.  | 
            
| 
                     OSCRI  | 
                
                     Content of the Process tab  | 
            
| 
                     DOCU_Title  | 
                
                    
                     in all objects (DOCU_Title) The attribute "state" is used system-internally and must not be changed. The attribute "type" shows the type of documentation: text = normal documentation  | 
            
| 
                     DOC  | 
                
                     Content of the Documentation tab Depending on the documentation type, the CDATA section contains the text or the XML structure.  | 
            
See also:
Export File of RemoteTaskManager
Filter Specifications