Knowledge Base > Automation Engine and Target Systems > NSK > Configuration of NSK-specific Parameters

Configuration of NSK-Specific Parameters

The NSK agent can be used to specify NSK-specific parameters in jobs (e.g. the TACL to be used or the user under which the job report should be created).

Specify the parameters in the following format:

== Parameter=Value

The agent searches the script for these lines and sets the parameters to the values you specified. TACL handles these lines as comments.

The following parameters are supported:

Parameter

Description

UC4_TACL_PROGRAM

Alternative TACL (Shell)

You can specify a different TACL if the standard TACL loads an environment which should not be used for AE jobs. This parameter is also helpful if several clients access a nonstop machine and require different TACL environments.

The agent uses the standard TACL if the specified TACL cannot be used and logs an error message.

UC4_TACL_PROCESSNAME

TACL process name

UC4_REPORT_USERNAME

User under which the job report should be created.

The value "DEFAULT_USER" can also be specified. In this case, the job report is created for the user under which the job runs.

UC4_REPORT_SECURITY

NonStop security string for the job report

Use this parameter carefully. An incorrect security string can have the effect that the agent cannot read or delete the job report.

Examples:

== UC4_TACL_PROGRAM=$SYSTEM.SYS03.TACL
== UC4_TACL_PROCESSNAME=$CAT2
== UC4_REPORT_USERNAME=SQLCMP.SMITH
== UC4_REPORT_SECURITY=NNNN

This is an optional function. The agent uses the particular default values for parameters which have not been set in the script.