| Section/Parameter | Description | 
|---|---|
| [GLOBAL] | |
| 
                     system=  | 
                
                     The name of the AE system. This entry must be identical to the entry in the INI file of the Automation Engine.  | 
            
| language= | 
                     The language in which the logging is processed. Entries for primary and secondary language. Allowed values: "E", "D", 
 "F" If there is no log in the primary language, a log in the secondary language is searched for.  | 
            
| 
                     timeout=  | 
                
                     The time in seconds during which the CallAPI waits for a response from AE. If this is exceeded, the CallAPI ends with a timeout error. Default value: 60  | 
            
| 
                     [USER]  | 
                
                     
  | 
            
| 
                     client=  | 
                
                     Login specifications: Client. Login data from this section is used when no login data is specified at service-program call  | 
            
| 
                     user=  | 
                
                     Login specifications: Name of the user.  | 
            
| 
                     dept=  | 
                
                     Login specifications: Department of the user.  | 
            
| 
                     pass=  | 
                
                     Login specifications: Password (optional).  | 
            
| 
                     [CP_LIST]  | 
                
                     The address of the communication processes in the AE system. Allowed formats:  | 
            
[GLOBAL] 
system=UC4
language=(E,D)
timeout=60
[USER]
client=3
user=smith
dept=uc4
pass=
[CP_LIST]
2217=uc4srv01
See also:
Notes for Configuration-File Adjustments