The utility AE DB Revision Report is called via the command line. Its complexity and content can be defined with parameters.
The following syntax should be applied:
UCYBDBRR -B -Cclient [-Farea -Ooutput file-D1start time-D2end time-X -A-IINI file-Llanguage]
The order of the parameters is freely selectable.
The line shown below serves as an example. All starting times and runtime modifications of client 3 which take place between 01.04. 20:00 and 02.04. 06:30 are output to the file C:\revision\report01.txt.
UCYBDBRR -B -C0003 -FSTART,RUN_MOD -OC:\revision\report01.txt -D120050401200000 -D220050402063000
All parameters except for -B and -C are optional. Hence, particular default values are used for the non-specified parameters in program calls. A list of these values including their descriptions is available in the document Start parameters.
Depending on the situation that has occurred, this utility supplies a particular return code when the process has finished.
| 
                     Return code  | 
                
                     Message number  | 
                
                     Description  | 
            
|---|---|---|
| 
                     0  | 
                
                     -  | 
                
                     The utility has successfully ended processing.  | 
            
| 
                     1  | 
                
                     U0036139  | 
                
                     Error occurred when loading INI-file settings  | 
            
| 
                     2  | 
                
                     U0036138  | 
                
                     Error: not possible to allocate memory for PCX  | 
            
| 
                     3  | 
                
                     U0021004  | 
                
                     Cannot find INI file  | 
            
| 
                     4  | 
                
                     U5005000  | 
                
                     No batch mode - please use parameter -B!  | 
            
| 
                     5  | 
                
                     U5005001  | 
                
                     No client has been defined!  | 
            
| 
                     6  | 
                
                     U0003301  | 
                
                     Could not allocate memory  | 
            
| 
                     7  | 
                
                     U5005008  | 
                
                     Processing was canceled. The output file cannot be opened.  | 
            
| 
                     8  | 
                
                     U0036134  | 
                
                     Error: cannot connect to AE source databaseA database is an organized collection of data including relevant data structures.  | 
            
| 
                     9  | 
                
                     U5005005  | 
                
                     Processing was canceled. The date definition is either invalid or does not have the correct format (YYYYMMDDhhmmss).  | 
            
| 10 | U5005012 | Processing was canceled. Versioning is in progress in client '&01'. Waiting for its end is not possible because the Automation Engine is not active. | 
See also:
Revision Report