 Notification Attributes
 Notification AttributesThe following table describes the attributes of a Notification object.
Predefined variables may be used in scripts, and script variables may be set to attributes retrieved via predefined variables.
 Header Tab
 Header Tab| Field | Attribute | Value | Access Via: | 
|---|---|---|---|
| Title | OBJECT_TITLE | User-defined, | GET_ATT, | 
| Created | USER_CREATED | The name of the User object, | GET_ATT, | 
| DATE_CREATED | Time stamp in the format "YYYY-MM-DD HH:MM:SS" | GET_ATT | |
| Modified | USER_MODIFIED | The name of the User object, | GET_ATT, | 
| DATE_MODIFIED | Time stamp in the format "YYYY-MM-DD HH:MM:SS" | GET_ATT | |
| MODIFY_COUNT | The number of object modifications. | GET_ATT | |
| Last Used 
 | LAST_USER | The name of the User object, | GET_ATT, | 
| LAST_DATE | The time stamp in the format "YYYY-MM-DD HH:MM:SS" | GET_ATT, | |
| USAGE_COUNT | Number of object usages | GET_ATT, | |
| Archive key 1 | ARCHIVE_KEY1 | User-defined, | GET_ATT, | 
| Archive key 2 | ARCHIVE_KEY2 | User-defined, | GET_ATT, | 
 Sync Tab
 Sync Tab| Field | Description | Attribute | Access Via: | 
|---|---|---|---|
| Assigned Sync object | SYNC_OBJECT | The name of a Sync object, a maximum of 20 characters must not be exceeded. | Change Program | 
 Attributes Tab
 Attributes Tab| Field | Attribute | Value | Access Via: | 
|---|---|---|---|
| Queue | QUEUE | The name of a queue, limited to 200 characters. | GET_ATT, :PUT_ATT, Change Program, predefined variable | 
| Group | GROUP | The name of a group, limited to 200 characters " " - For an immediate start | GET_ATT, :PUT_ATT, Change Program, predefined variable | 
| Int. account | INT_ACCOUNT, INT_ACC, K | User-defined, | GET_ATT, | 
| Priority | CO_PRIORITY | "HIGH" - High priority | GET_ATT, | 
| Type | CO_TYPE | "QUESTION" - Request | GET_ATT, | 
| SNMP connection | CO_SNMP | "Y" - Activate SNMP connection | GET_ATT, | 
| Send Email | CO_EMAIL | "Y" - Send Email | GET_ATT, | 
| Escalation - After ... Min. without response | CO_RISING_TIME | The time in minutes, any value between "1" and "9999" Reading the attribute creates a 16-figure value with leading zeros. | GET_ATT, | 
| Escalation - Notification | CO_RISING_NAME | The name of a notification, | GET_ATT, | 
| Automation Engine priority | AE_PRIORITY | User-defined,  | GET_ATT, | 
| TimeZone | TIMEZONE | User-defined, | GET_ATT, | 
| Generate at runtime | GEN_AT_RUNTIME | "Y" - Generation at runtime. | GET_ATT | 
| Tasks running parallel - Max. number | MAX_PARALLEL_TASKS | User-defined,  | GET_ATT, | 
| Tasks running parallel - Else | MAX_PARALLEL_ELSE | "WAIT" - Notification waits until execution is possible. | GET_ATT, | 
| Automatically deactivate when finished | AUTO_DEACT | "NEVER" - Never deactivate automatically. | GET_ATT, | 
| Error-free status (for After an error-free restart) | AUTO_DEACT_ERROR_FREE | Task status, 
                         | GET_ATT, | 
| Time delay minutes (for Always) | AUTO_DEACT_DELAY | User-defined, | GET_ATT, | 
 Notification Tab
 Notification Tab| Field | Attribute | Value | Access Via: | 
|---|---|---|---|
| Subject | SUBJECT | User-defined, limited to 255 characters. | GET_ATT, :PUT_ATT, predefined variable | 
| Message 
 | CALL_TEXT | User-defined | GET_ATT, | 
| Script variables that are used in texts and should be changed must be used within the first 256 characters. All script variables that are use afterward will not be considered. | |||
| Attach reports from Task (RunID) | ATTACH_REPORTS_RUNID | User-defined, limited to 32 characters. | GET_ATT, :PUT_ATT, predefined variable | 
| Source | ATTACH_REPORTS_SOURCE | "DB" - Database "EXTERNAL" - External files "ALL" - All | GET_ATT, :PUT_ATT, via script variable, predefined variable | 
| Attach a file from Automation Engine (path and file name) | ATTACH_FILE | User-defined, limited to 255 characters. | GET_ATT, :PUT_ATT, predefined variable | 
 Recipients Tab
 Recipients Tab| Field | Attribute | Value | Access Via: | 
|---|---|---|---|
| Assigned calendar | CALENDAR | The name of a calendar, limited to 200 characters. | :ADD_ATT, Change Program | 
| Assigned calendar keyword | CALENDAR_KEYWORD | The name of a calendar keyword, limited to 200 characters. | ADD_ATT, Change Program | 
| Recipients | RECIPIENT | Recipients can be added to the runtime by using the script element ADD_ATT and removed with REMOVE_ATT. | :ADD_ATT, | 
 Runtime Tab
 Runtime Tab| Field | Attribute | Value | Access Via: | 
|---|---|---|---|
| Return code <= | MAX_RETCODE | User-defined, | GET_ATT, | 
 Process Tab
 Process Tab| Field | Attribute | Value | Access Via: | 
|---|---|---|---|
| The string in the Process tab of the job should be changed. | SCRIPT | 
 | Change Program | 
 Notification Attributes Not on a Tab
 Notification Attributes Not on a Tab| Field | Attribute | Value | Access Via: | 
|---|---|---|---|
| Object name | OBJECT_NAME | User-defined, | Change Program | 
| Mode UserInterface | DCMODUS | "Y" - UserInterface is active | GET_ATT | 
See also:
Notification
Attributes
:PUT_ATT statement
GET_ATT function
:ADD_ATT statement
:REMOVE_ATT statement
AE DB Change