| Section/Parameter | Description | 
|---|---|
| [GLOBAL] | |
| system= | The name of the AE system. This entry must be identical to the entry in the INI file of the Automation Engine. | 
| helplib= | The name of the message file, | 
| language= | Language in which the logging is executed. Entries for primary and secondary language. Allowed values: "E", "D", 
 "F" If there is no log in the primary language, a log in the secondary language is searched for. | 
| logging= | The name of the log file. The number signs serve as place holders for a series in numerical order. When starting the agent, the log files are renamed so that the most current log file is always the one with the number "00". | 
| logcount= | The number of stored log files. | 
| timeout= | The time in seconds during which the CallAPI waits for a response from AE. If this is exceeded, the CallAPI ends with a timeout error. Default value: 60 | 
| TRACE | Trace designation. Allowed values:
 If the trace parameter is set to 1, additional information is written to STDOUT | 
| [USER] | 
 | 
| client= | Login specifications: Client. Login data from this section is used when no login data is specified at service-program call | 
| user= | Login specifications: Name of the user. | 
| dept= | Login specifications: Department of the user. | 
| pass= | Login specifications: Password (optional). | 
| [CP_LIST] | The address of the communication processes in the AE system. Allowed formats: | 
[GLOBAL]
system=UC4
helplib=UCMSL
language=E,D
logging=$data01.uc4.LOGA##
logcount=10
timeout=60
TRACE=1
[USER]
client=
user=
dept=
pass=
[CP_LIST]
2217=uc4srv01
; 2218=uc4srv02
See also:
Notes for Configuration-File Adjustments