User Guide > Objects > Alphabetical Listing > Script Attributes

Script Attributes

The following table describes the attributes of a Script object.

Predefined variables may be used in scripts, and script variables may be set to attributes retrieved via predefined variables.

Header Tab

Field

Attribute

Value

Access Via:

Title

OBJECT_TITLE

User-defined,
limited to 255 characters.

GET_ATT,
:PUT_ATT (Pre-Process, Process),
predefined variable

Created

USER_CREATED

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

DATE_CREATED

Time stamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT

Modified

USER_MODIFIED

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

DATE_MODIFIED

Time stamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT

MODIFY_COUNT

The number of object modifications.

GET_ATT

Last Used

 

LAST_USER

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

LAST_DATE

The time stamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT,
predefined variable

USAGE_COUNT

Number of object usages

GET_ATT,
predefined variable

Archive key 1

ARCHIVE_KEY1

User-defined,
limited to 60 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Archive key 2

ARCHIVE_KEY2

User-defined,
limited to 20 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

 Sync Tab

Field Description Attribute Access Via:
Assigned Sync object SYNC_OBJECT The name of a Sync object,
a maximum of 20 characters must not be exceeded.
Change Program

 Attributes Tab

Description

Attribute

Value

Access Via

Queue QUEUE Name of a queue,
maximum 200 characters
GET_ATT,
:PUT_ATT,
Change Program,
predefined variable
Group GROUP Name of a group,
maximum 200 characters
" " - for immediate start
GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Int. Account

INT_ACCOUNT, INT_ACC, K

User-defined,
maximum 16 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Automation Engine priority

UC4_PRIORITY

User-defined,
Value between "0" and "255"

GET_ATT,
:PUT_ATT,
predefined variable

TimeZone

TIMEZONE

Name of a TimeZone object
maximum 8 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Generate at runtime

GEN_AT_RUNTIME

"Y" - Generation at runtime
"N" - Generation at activation time

GET_ATT

Tasks running parallel - Max. number

MAX_PARALLEL_TASKS

User-defined,
Value between "0" and "99999"

GET_ATT,
:PUT_ATT,
predefined variable

Tasks running parallel - Else

MAX_PARALLEL_ELSE

"WAIT" - Script waits until processing is possible
"ABEND" - Script is interrupted 

GET_ATT,
:PUT_ATT

Automatically deactivate when finished

AUTO_DEACT

"NEVER" - Never deactivate automatically.
"ENDED_ERROR_FREE" - In the case of error-free processing, deactivate automatically.
"RESTART_ERROR_FREE" - In the case of an error-free restart, deactivate automatically. 
"ALWAYS" - Always deactivate automatically.

GET_ATT,
:PUT_ATT

Time delay minutes (for Always)

AUTO_DEACT_DELAY

User-defined,
any value between "0" and "99".

GET_ATT,
:PUT_ATT

Error-free status (for After an error-free restart)

AUTO_DEACT_ERROR_FREE

Task status,
limited to 20 characters

GET_ATT,
:PUT_ATT

Runtime Tab

Field

Attribute

Value

Access Via:

Return code <=

MAX_RETCODE

User-defined,
limited to 11 numbers.

GET_ATT,
:PUT_ATT (Pre-Process, Process)

Process Tab

Field

Attribute

Value

Access Via:

String in the script of the Script object which should be changed

SCRIPT

 

Change Program

Script Attributes Not on a Tab

Field

Attribute

Value

Access Via:

Object name

OBJECT_NAME

User-defined,
limited to 200 characters.

Change Program

Mode UserInterface

DCMODUS

"Y" - UserInterface is active
"N" - No UserInterface is active

GET_ATT

 

See also:

Script
Attributes

:PUT_ATT

GET_ATT
function

AE DB Change