| Section/Parameter | Description | 
|---|---|
| (GLOBAL) | |
| 
                     system=  | 
                
                     Name of the AE system This entry must be identical to the entry in the INI file of the Automation Engine.  | 
            
| 
                     helplib=  | 
                
                     Name of the message file  | 
            
| language= | 
                     Language in which the logging is executed. Entries for primary and secondary language. Allowed values: "E", "D", 
 "F" If there is no log in the primary language, a log in the secondary language is searched for.  | 
            
| 
                     timeout=  | 
                
                     Time in seconds during which the CallAPI waits for a response from AE. If this is exceeded, the CallAPI ends with a timeout error. Default value: 60 With the parameter timeout=0 being used, the CallAPI waits (without time limit) until the Automation Engine acknowledges.  | 
            
| 
                     codetable=  | 
                
                     Name of the CodeTable object that should be used by the CallAPI The IBM standard code table is used if nothing is specified in this parameter.  | 
            
| queue= | 
                     Specification of a particular Queue object in which the CallAPI should be executed. This parameter overrides the setting API_QUEUEin the variable UC_CLIENT_SETTINGS.  | 
            
| 
                     (USER)  | 
                
                     
  | 
            
| 
                     client=  | 
                
                     Logon specifications: Client Logon data from this section is used when no logon data is specified at service-program call  | 
            
| 
                     user=  | 
                
                     Logon specifications: Name of the user  | 
            
| 
                     dept=  | 
                
                     Logon specifications: Department of the user  | 
            
| 
                     pass=  | 
                
                     Logon specifications: Password (optional)  | 
            
| 
                     (CP_LIST)  | 
                
                     Address of the communication processes in the AE system Allowed formats:  | 
            
(GLOBAL)
system=UC4
helplib='UC4.UC.MSL'
language=(E,D)
timeout=60
;queue=
(USER)
client=
user=
dept=
pass=
(CP_LIST)
2217=uc4srv01
; 2218=uc4srv02
CallAPI trace for z/OS agents is set activated/deactivated on the command line.
Allowed values:
"N" (default) = Deactivate trace
"Y" = Activate trace
For example:
TRACE=Y
Once tracing has been activated with TRACE=Y, the CallAPI writes the trace to the location specified in the TRACE DD card:
//TRACE DD SYSOUT=*
or
//TRACE DD DSN=datsetname,....
See also:
Notes for Configuration-File Adjustments