Automation Engine Script Guide > Ordered by Function > System Conditions and Settings > :TERMINATE

:TERMINATE

Script Statement: Ends an agent, the agents of an agent group, a work or communication process

Syntax

:TERMINATE [Connection], Name

Syntax

Description/Format

Connection

Type of connection
Format: AE name, script literal or script literal

Allowed values: "HOST" (default value), "HOSTGROUP" and "SERVER"
"HOST" = Agent
"HOSTGROUP" = Agents of an agent group
"SERVER" = Work or communication process

Name

Name of an agent, agent group, work or communication process
Format: script literal or script variable

Comments

This script statement can be used to end agents and work and communication processes. The parameter Connection does not have to be indicated. A colon must be set if it is not used.

Instead of specifying an individual agent, you can also indicate an agent group. The termination applies to all agents that belong to this group.

If the connection to an agent should end on a temporary basis, we recommend using the script element  :DISCONNECT. In this case, the agent reconnects to the Server when the next signal for an agent check is sent. With :SHUTDOWN all work and communication processes of the AE system can be terminated.

 The right to "cancel" server processes or agents is required to execute this script statement.

Examples

The example below terminates a work process.

:TERMINATE SERVER,"AE#WP001"

In this example, the agent "WIN21" is terminated. The type of connection is not indicated.

:TERMINATE ,"WIN21"

 

See also:

Script element/function Description

:DISCONNECT

Disconnects a connection to the AE system.
:SHUTDOWN Ends an AE system.

MODIFY_SYSTEM

Processes ServiceManager actions or queue modifications.

Script Elements - System Conditions and Settings

About Scripts
Script Elements - Alphabetical Listing

Script Elements - Ordered by Function