Export File StructureThe table shown below describes the XML file structure of an Event object and explains the individual elements.
|
Element |
Description |
|---|---|
|
uc-export |
Main element of the export file clientvers = Automation Engine version in which the export file was created |
|
EVNT |
client = The client. |
|
XHEADER |
XHEADER in executable objects see object types The attribute "state" is used system-internally and must not be changed. |
|
Title |
User-defined, max. 255 characters |
|
Created |
Format: |
|
Modified |
Format:
|
|
LastUsed |
Format: |
|
ArchiveKey1 |
User-defined, Attribute: ARCHIVE_KEY1 |
|
ArchiveKey2 |
User-defined, Attribute: ARCHIVE_KEY2 |
|
ExtRepDef |
ExtRepDef:
Default value (UC_CLIENT_SETTINGS) Allowed values: "1" (selected) and "0" (not selected) Only one of the three options can be selected. |
|
SYNCREF |
only for executable objects The attribute "state" is used system-internally and must not be changed. |
|
Syncs |
Attributes per Sync object definition (row): Abend = Action when the task is canceled Up to 40 Sync object definitions are allowed. |
|
CALEREF |
For Event objects The attribute "state" is used system-internally and must not be changed. |
|
Cond |
Attributes per Calendar definition (row): CaleKeyName = Calendar keyword |
|
ATTR_EVNT |
In all objects except for User, UserGroup, Cockpit, CodeTable, Documentation, Include and Login (ATTR_Object type) objects. The attribute "state" is used system-internally and must not be changed. |
|
StartType |
Name of a group, Attribute: START_TYPE |
|
IntAccount |
User-defined, Attribute: INT_ACCOUNT, INT_ACC or K |
|
ActAtRun |
Allowed values: "1" (selected) and "0" (not selected) Attribute: GEN_AT_RUNTIME |
|
UC4Priority |
User-defined, Attribute: UC4_PRIORITY |
|
MaxParallel2 |
Maximal number of tasks running parallel User-defined, Attribute: MAX_PARALLEL_TASKS |
|
MpElse1 |
Maximal number of tasks running parallel - Else MpElse1: wait Allowed values: "1" (selected) and "0" (not selected) Attribute: MAX_PARALLEL_ELSE |
|
TZ |
Name of a TimeZone object, Attribute: TIMEZONE |
|
EVNT |
For Event objects The attribute "state" is used system-internally and must not be changed. |
|
RepeatTypeR |
RepeatTypeR: Repeated Allowed values: "1" (selected) and "0" (not selected) Attribute: EVENT_REPEAT Only one of the three options can be selected. |
|
EventTypeTT |
EventTypeTT: Execution in intervals of n
minutes Allowed values: "1" (selected) and "0" (not selected) Only one of the two options can be selected.
TimePeriodTT: Minutes TimePeriodTS: Point in time |
|
TExecTypeT |
TExecTypeT: After time is expired Allowed values: "1" (selected) and "0" (not selected) Attribute: EVENT_FIRST_EXEC Only one of the two options can be selected. |
|
TExecTypeN |
TExecTypeN: Do not execute Allowed values: "1" (selected) and "0" (not selected) Attribute: EVENT_START_AFTER_SCH Only one of the two options can be selected. |
|
RUNTIME |
only for executable objects The attribute "state" is used system-internally and must not be changed. |
|
MaxRetCode |
Value ranging between "0" and "2147483647" Attribute: MAX_RETCODE |
|
FcstStatus |
Format: "system return code|status text" see also return codes |
|
Ert |
Time in seconds Value ranging between "0" and "35999999" |
|
ErtMethodDef |
ErtMethodDef: Default value (UC_CLIENT_SETTINGS) Allowed values: "1" (selected) and "0" (not selected) Only one of the three options can be selected. |
|
ErtFix |
Fixed value for ERT calculation This value is part of the fixed value calculation method (ErtMethodFix). Time in seconds Value ranging between "0" and "35999999" |
|
ErtDynMethod |
These values are part of the dynamic calculation method. ErtDynMethod: Method ErtCnt: Runs ErtCorr: Percentage of runs ErtIgn: Deviation in percent ErtIgnFlg: Consider deviation ErtMinCnt: Minimum runs |
|
MrtMethodNone |
Monitoring the maximum runtime (MRT) MrtMethodNone: None Allowed values: "1" (selected) and "0" (not selected) Only one of the four options can be selected. |
|
MrtFix |
Fixed value for MRT monitoring This value is part of the fixed value monitoring method (MrtMethodFix). Time in seconds Value ranging between "0" and "35999999" |
|
MrtErt |
This value is part of the monitoring method Ert + (MrtMethodErt). Value ranging between "0" and "999" |
|
MrtDays |
These values are part of the monitoring method Curr. Date + (MrtMethodDate). MrtDays: Days MrtTime: Time MrtTZ: TimeZone |
|
SrtMethodNone |
Monitoring the minimum runtime (SRT) SrtMethodNone: None Allowed values: "1" (selected) and "0" (not selected) Only one of the three options can be selected. |
|
SrtFix |
Fixed value for SRT monitoring This value is part of the monitoring method fixed value (SrtMethodFix). Time in seconds Value ranging between "0" and "35999999" |
|
SrtErt |
This value is part of the monitoring method ERT - (SrtMethodErt). Value ranging between "0" and "999" |
|
MrtCancel |
Cancel/quit (only for MRT monitoring) Allowed values: "1" (selected) and "0" (not selected) |
|
MrtExecute |
MrtExecute: Allowed values: "1" (selected) and "0" (not selected) MrtExecuteObj: |
| DYNVALUES |
in all executable object except for the Cockpit (CPIT) The attribute "state" is used system-internally and must not be changed. |
| dyntree |
List of object variables and PromptSet assignments Definition (node) of the "Values" area and of each PromptSet assignment with the following attributes: content = Content available. Allowed values: "0" (no), "1" (yes)
Structure of the "Values" area (node id="VALUE") Values: Table with object variables Mode: Inherit from parent
Structure of PromptSet assignment definitions (node id="PRPTS"): PROMPTSET definition with the following attributes: PROMPTBOX with the PromptSet element definitions and their values: |
|
PRE_SCRIPT |
only in jobs and events (Process tab" in events) The attribute "state" is used system-internally and must not be changed. |
|
PSCRI |
Content of the Process tab |
|
SCRIPT |
only in executable objects Exception: In Event objects, it is the "!Process" tab. The attribute "state" is used system-internally and must not be changed. |
|
MSCRI |
Content of the Process tab |
|
DOCU_Title |
in all objects (DOCU_Title) The attribute "state" is used system-internally and must not be changed. The attribute "type" shows the type of documentation: text = normal documentation |
|
DOC |
Content of the Documentation tab Depending on the documentation type, the CDATA section contains the text or the XML structure. |
|
Element |
Description |
|---|---|
|
EVNT_FILE |
in File-System Events The attribute "state" is used system-internally and must not be changed. |
|
HostDst |
HostDst: Name of an agent Path: Path in the file system FileType: Type of monitoring Operator: Comparison operand Value: Comparison value Unit: Unit |
BS2000
|
Element |
Description |
|---|---|
|
EVNT_CONS |
in Console Events The attribute "state" is used system-internally and must not be changed. |
|
HostDst |
HostDst: Name of the agent STD_Filter: Message filter |
z/OS
|
Element |
Description |
|---|---|
|
EVNT_CONS |
in Console Events The attribute "state" is used system-internally and must not be changed. |
|
HostDst |
HostDst: Name of the agent MVS_SysName: System name MVS_OSName: OS name MVS_Filter: Message filter |
OS/400
|
Element |
Description |
|---|---|
|
EVNT_CONS |
HostDst: Name of the agent OS400_MsgType: Type of message OS400_Severity: Valuation OS400_Filter: message filter |
|
HostDst |
HostDst: Name of the agent OS400_MsgType: Type of message OS400_Severity: Valuation OS400_Filter: message filter |
SAP
|
Element |
Description |
|---|---|
|
EVNT_CONS |
in Console Events The attribute "state" is used system-internally and must not be changed. |
|
HostDst |
HostDst: Name of the agent R3_EventSubType: Data source R3_Filter: event filter |
Windows
|
Element |
Description |
|---|---|
|
EVNT_CONS |
in Console Events The attribute "state" is used system-internally and must not be changed. |
|
HostDst |
HostDst: Name of the agent WINDOWS_EventSubType: Type WINDOWS_Source: Source WINDOWS_Category: Category WINDOWS_Filter: Message filter |
|
Element |
Description |
|---|---|
|
EVNT_DB |
In Database Events |
| Op1_type Op2_type |
Source selection for value 1 and value 2. Op1_* - Value 1 Allowed values: |
| Op1_sql Op1_host Op1_server Op1_login Op1_db Op1_file Op2_sql Op2_host Op2_server Op2_login Op2_db Op2_file |
Op1_* - Value 1 sql - SQL |
| Op1_keyword Op1_vara Op2_keyword Op2_vara |
Op1_* - Value 1 vara - VARA - Variable object |
| Op1_static Op2_static |
Op1_static - Statistical value for value 1 |
See also:
Export File of an Event
XML File Structure for Imports and Exports
Event Types