Definition of table: OH - object header

generated: 09.12.2016 10:28:30
by UC2010.accdb

AE Database 12.0 (Step 013)



Name Type Len Attributes Description
OH_Client Integer 2 UC: Null=False client
OH_OType Text 8 UC: Null=False object type
OH_Name Text 200 UC: Null=False object name
OH_Idnr Long Integer 4 UC: Typ=Zähler Null=False primary key of the object header
OH_Title Text 255 UC: Null=True title
OH_CrUserIdnr Long Integer 4 UC: Null=True user who created this object
OH_CrDate Date/Time 8 UC: Null=True date of creation
OH_ModUserIdnr Long Integer 4 UC: Null=True user who modified this object
OH_ModDate Date/Time 8 UC: Null=True date of modification
OH_ModCnt Long Integer 4 UC: Null=True modification counter
OH_LastUserIdnr Long Integer 4 UC: Null=True user who lately used this object
OH_LastDate Date/Time 8 UC: Null=True date of last use
OH_LastCnt Long Integer 4 UC: Null=True usage counter
OH_JPP_Count Integer 2 UC: Null=True number of JPP
OH_Share Text 1 UC: Null=True is this object visible in other client (only for client 0) l=readable R=referenceable
OH_C0Ref Byte 1 UC: Typ=Boolean Null=True flag if this is a reference to client 0
OH_NoStatUpd Byte 1 UC: Null=True extended reports to be written (Header Tab): 0=Default (UC_CLIENT_SETTINGS), 1=All, 2=None
OH_DeleteFlag Byte 1 UC: Null=True delete flag
OH_ExpFlag Byte 1 UC: Null=True export flag
OH_MaxWait Long Integer 4 UC: Null=True number of seconds to wait before execution
OH_MaxParallel2 Integer 2 UC: Null=True maximum number of parallel running jobs
OH_MPElse Integer 2 UC: Null=True bit array for the checkpoint and what should happen if the maximum number is exceeded
OH_Archive1 Text 60 UC: Null=True archive key 1
OH_Archive2 Text 20 UC: Null=True archive keyf 2
OH_OpenUserIdnr Long Integer 4 UC: Null=True opened by user
OH_OpenDate Date/Time 8 UC: Null=True opened by user since ...
OH_MaxRetCode Long Integer 4 UC: Null=True up to this retcode the activity is ENDED_OK
OH_MrtMethod Long Integer 4 UC: Null=True Method f.max. Runtime (bitmask) 0=no audit, 1=fix in seconds, 2=fix time, 4=ERT+xx%, 256=Cancel, 512=Start Object 65536=SRT in seconds, 131072=SRT ERT+xx%
OH_Mrt Long Integer 4 UC: Null=True maximum execution time in seconds (should be OH_MRT)
OH_MrtTime Text 6 UC: Null=True Max. runtime in time ddhhmm
OH_MrtErt Integer 2 UC: Null=True MRT=ERT+xx%
OH_MrtExecute Text 200 UC: Null=True Object start for runtime audit
OH_Frt Long Integer 4 UC: Null=True Fixed runtime in seconds
OH_Ert Long Integer 4 UC: Null=True Estimated runtime in seconds
OH_ErtCnt Integer 2 UC: Null=True last x runs to check
OH_ErtCorr Integer 2 UC: Null=True + xx %
OH_ErtIgn Integer 2 UC: Null=True Ignore > xx% deviation
OH_ErtMinCnt Integer 2 UC: Null=True Minimum runs to check
OH_ErtMethod Long Integer 4 UC: Null=True Method (bitmask) 0=default, 1=fix, 2=avg, 4=max, 8=linearregression 256=Ignore deviation
OH_ErtTrend Long Integer 4 UC: Null=True Trend (bitmask) 0=undefined, 8=constant upward, 4=upward, 2=downward, 1=constant downward
OH_LastRuns Memo 0 UC: Typ=binary L=100 Null=True Last 25 runs in seconds
OH_Srt Long Integer 4 UC: Null=True SRT in Seconds
OH_SrtErt Integer 2 UC: Null=True SRT=ERT+xx%
OH_FcstStatus Long Integer 4 UC: Null=True Default status for forecast (i.e. STOP NOMSG)
OH_UC4Priority Integer 2 UC: Null=True UC4 priority
OH_TZ Text 8 UC: Null=True Timezone for this object and script
OH_MrtTZ Text 8 UC: Null=True Timezone for max. Runtime when a fixed time is used
OH_RefIdnr Long Integer 4 UC: Null=True Version Control: Reference to OH_IDNR of original object if OH_DeleteFlag = 2
OH_OX_ContentLen Long Integer 4 UC: Null=True Length for OX_Content of OX Table
OH_ExtFlag Text 1 UC: Null=True 1=This task is used as an external dependency
OH_OpenSession Long Integer 4 UC: Null=True SessionId of the User Session which set OH_Open Fields
OH_OV_Flag Byte 1 UC: Typ=Boolean Null=True 1=OV is defined, 0=there is no OV
OH_OV_Mode Byte 1 UC: Null=True Mode for heritage of values (0=InheritAll, 1=InheritDefined, 2=InheritNone)
OH_HostFsc Text 200 UC: Null=True Filescan Host
OH_LoginFsc Text 200 UC: Null=True Filescan Login Object
OH_MrcExecute Text 200 UC: Null=True Alarm object for max retcode
OH_PPFInherit Text 1 UC: Null=True OutputScanTarget (N=no children,Y=with children,C=children only)
OH_HostAttrTypeDst Text 8 UC: Null=True Type of the Destination Host.
OH_Queue Text 200 UC: Null=True Name of the Queue the Object runs within
OH_ChildQueue Text 200 UC: Null=True The children are assigned to this Queue
OH_OPU_Flag Byte 1 UC: Typ=Boolean Null=True Object has OPU subtables
OH_OEO_Flag Byte 1 UC: Typ=Boolean Null=True Object has OEOs
OH_ChildFlags Text 32 UC: Null=True Flags for Subtables
OH_IsTemplate Byte 1 UC: Typ=Boolean Null=True Object is a template
OH_Icon Text 8 UC: Null=True object icon
OH_RollbackFlag Byte 1 UC: Typ=Boolean Null=True Rollback is enabled for object
OH_Inactive Byte 1 UC: Typ=Boolean Null=True SLO active/inactive
OH_SubType Text 8 UC: Null=True OType specific SubType
OH_DeactDelay Long Integer 4 UC: Null=True delay in minutes
OH_AutoDeact Text 1 UC: Null=True deactivate autom. when finished: J/N/A/F J=during first error-free program run, A=always, N=no, F=when errorfree
OH_DeactWhen Text 30 UC: Null=True ok state for autom. deactivation
OH_AEVersion Text 8 UC: Null=True AE system version


Indexes:

Name Fields
NK_OH_DelFlag OH_DeleteFlag, OH_Client, OH_OpenUserIdnr, OH_Idnr
NK_OH_ModDate OH_OType, OH_ModDate
NK_OH_MrtExecute OH_MrtExecute, OH_Client
NK_OH_OpenSess OH_OpenSession
NK_OH_OType OH_Client, OH_OType, OH_Name, OH_Idnr
NK_OH_RefIdnr OH_RefIdnr, OH_ModCnt, OH_Idnr
NK_OH_Reorg OH_Client, OH_DeleteFlag, OH_ModDate, OH_RefIdnr, OH_Idnr
NK_OH_Search OH_Client, OH_DeleteFlag, OH_OType, OH_Name, OH_Idnr
NK_OH_Search2 OH_Client, OH_Name
PK_OH OH_Idnr
UK_OH_Name OH_Name, OH_Client


Return to the Index File