JPP_OH_Idnr |
int |
NUMBER(38,0) |
int |
int |
false |
ID of the object. |
JPP_Lnr |
smallint |
NUMBER(38,0) |
smallint |
smallint |
false |
Sequenced number of the workflow tasks. |
JPP_OType |
varchar (8) |
VARCHAR2 (8 CHAR) |
varchar(8) |
varchar (8) |
true |
Type of the workflow task. |
JPP_Object |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
varchar (200) |
true |
Name of the workflow task. |
JPP_Comment |
varchar (40) |
VARCHAR2 (40 CHAR) |
varchar(40) |
varchar (40) |
true |
Comment |
JPP_ErlstStTime |
varchar (10) |
VARCHAR2 (10 CHAR) |
varchar(10) |
varchar (10) |
true |
Earliest start time of the workflow task. |
JPP_LtstStTime |
varchar (10) |
VARCHAR2 (10 CHAR) |
varchar(10) |
varchar (10) |
true |
Latest start time of the workflow task. |
JPP_LtstEndTime |
varchar (10) |
VARCHAR2 (10 CHAR) |
varchar(10) |
varchar (10) |
true |
Latest end time of the workflow task. |
JPP_WElse |
char (1) |
CHAR (1 CHAR) |
char(1) |
char (1) |
true |
Defines the action that will be triggered, if the status of any predecessor is not successful. S = skip, H = halt, A = abend, X = block and abort |
JPP_WCType |
char (1) |
CHAR (1 CHAR) |
char(1) |
char (1) |
true |
Conjunction for the pre-conditions. |
JPP_CCType |
char (1) |
CHAR (1 CHAR) |
char(1) |
char (1) |
true |
Calendar condition of the workflow task. 1 = and, 2 = equal, 3 = not equal, 4 = ext. |
JPP_PreCnt |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
Number of this workflow task's predecessors. |
JPP_Row |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
y-coordinate of the workflow task (for the graphical representation within the workflow editor/monitor). |
JPP_Col |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
x-coordinate of the workflow task (for the graphical representation within the workflow editor/monitor). |
JPP_WhenExecute |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
varchar (200) |
true |
Name of the object, that will be triggered, if the status of any predecessor is not successful. |
JPP_Active |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
bit 1: active/inactive, bit 2: hold/normal |
JPP_RWhen |
varchar (30) |
VARCHAR2 (30 CHAR) |
varchar(30) |
varchar (30) |
true |
Possible success status of the line's precondition (e.g. ANY_OK, ENDED_SKIPPED, ENDED_NOT_OK). |
JPP_RExecute |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
varchar (200) |
true |
Name of the object, that will be triggered, if the workflow task does not end successfully. |
JPP_RElse |
int |
NUMBER(38,0) |
int |
int |
true |
Workflow action, that will be triggered, if the workflow task does not end successfully. 1 = halt, 2 = ignore, 3 = abend workflow |
JPP_RRepMTimes |
int |
NUMBER(38,0) |
int |
int |
true |
Maximum number of repeats, if the workflow task does not end successfully. |
JPP_RRepWait |
int |
NUMBER(38,0) |
int |
int |
true |
Wait time between retries in minutes. |
JPP_MrtMethod |
int |
NUMBER(38,0) |
int |
int |
true |
Method for the maximum runtime. 0 = no audit, 1 = fix in seconds, 2 = fix time, 4 = ERT+xx%, 256 = Cancel, 512 = Start Object, 1024 = worflow overwrites object settings |
JPP_Mrt |
int |
NUMBER(38,0) |
int |
int |
true |
Maximum runtime (MRT) in seconds. |
JPP_MrtTime |
char (6) |
CHAR (6 CHAR) |
char(6) |
char (6) |
true |
Maxium runtime in time. Format: ddhhmm |
JPP_MrtErt |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
MRT = ERT + xx% |
JPP_MrtExecute |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
varchar (200) |
true |
Object to start for runtime audit. |
JPP_TcpATime |
char (6) |
CHAR (6 CHAR) |
char(6) |
char (6) |
true |
after time > time |
JPP_TcpExecute |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
varchar (200) |
true |
Object to start. |
JPP_Srt |
int |
NUMBER(38,0) |
int |
int |
true |
Shortest runtime (SRT) in seconds. |
JPP_SrtErt |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
SRT = ERT + xx% |
JPP_TcpATimetTZ |
varchar (8) |
VARCHAR2 (8 CHAR) |
varchar(8) |
varchar (8) |
true |
Timezone for time check point. |
JPP_ErlstStTimeTZ |
varchar (8) |
VARCHAR2 (8 CHAR) |
varchar(8) |
varchar (8) |
true |
Timezone for erleast start time. |
JPP_LtstTimeTZ |
varchar (8) |
VARCHAR2 (8 CHAR) |
varchar(8) |
varchar (8) |
true |
Timezone for latest time. |
JPP_MrtTZ |
varchar (8) |
VARCHAR2 (8 CHAR) |
varchar(8) |
varchar (8) |
true |
Timezone for max. Runtime when a fixed time is used. |
JPP_ConFlag |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
Indicates whether or not the workflow task is connected to the end task. |
JPP_RExecFlag |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
Indicates when the alarm object is triggered. 0 = execute after each unsuccessful execution, 1 = execute only after all retries are unsuccessful |
JPP_PreCntExt |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
Number of external predecessors. |
JPP_ParentObject |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
varchar (200) |
true |
Name of the workflow. (only for external dependencies) |
JPP_ExtWhen |
varchar (30) |
VARCHAR2 (30 CHAR) |
varchar(30) |
varchar (30) |
true |
External Precondition: Possible success status (e.g. ANY_OK, ENDED_SKIPPED, ENDED_NOT_OK). |
JPP_ExtSLTType |
char (1) |
CHAR (1 CHAR) |
char(1) |
char (1) |
true |
External Precondition: Type of the satisfaction lead time. 0 = since last run, 1 = after start of workflow, 2 = within time in seconds |
JPP_ExtSLTWithin |
int |
NUMBER(38,0) |
int |
int |
true |
External Precondition: Time in seconds |
JPP_ExtElse |
char (1) |
CHAR (1 CHAR) |
char(1) |
char (1) |
true |
External Precondition: Workflow action that is triggered, if the precondition fails. 0 = wait, 1 = skip, 2 = abend workflow |
JPP_ExtElseAlarm |
char (1) |
CHAR (1 CHAR) |
char(1) |
char (1) |
true |
External Precondition: Indicates whether or not an alarm object is triggered, if the precondition fails. 0 = no, 1 = yes |
JPP_ExtTimeout |
int |
NUMBER(38,0) |
int |
int |
true |
External Precondition: Timeout in seconds. |
JPP_ExtTimeoutE |
char (1) |
CHAR (1 CHAR) |
char(1) |
char (1) |
true |
External Precondition: Workflow action that is triggered, if the precondition timeout occurs. 0 = wait, 1 = Skip, 2 = abend workflow |
JPP_ExtTimeoutA |
char (1) |
CHAR (1 CHAR) |
char(1) |
char (1) |
true |
External Precondition: Indicates whether or not an alarm object is triggered, if the precondition timeout occurs. 0 = no, 1 = yes |
JPP_ExtExecute |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
varchar (200) |
true |
External Precondition: Name of the alarm object that is executed, if the precondition fails. |
JPP_TimeoutFlag |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
External Precondition: Indicates whether or not the AE checks for the timeout. 0 = off, 1 = on |
JPP_JPPV_Flag |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
Indicates whether or not workflow task has object variables in its task properties. |
JPP_PreCondFlag |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
Indicates whether or not workflow task has preconditions. |
JPP_PostCondFlag |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
Indicates whether or not workflow task has postconditions. |
JPP_Alias |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
varchar (200) |
true |
Display name of the workflow task. |
JPP_ParentAlias |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
varchar (200) |
true |
Display name of the workflow task in external dependencies. |
JPP_ChildFlags |
char (16) |
CHAR (16 CHAR) |
char(16) |
char (16) |
true |
Flags for child tables. |
JPP_ShowPrompt |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
Indicates whether or not prompts will be shown. |
JPP_PromptAtGen |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
Show prompt during workflow generation or workflow task generation. |
JPP_BranchType |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
Type of branch in case of a IF or FOREACH workflow. IF: 1 = true, 2 = false, FOREACH: 1 = loop path, 2 = end path |
JPP_RunPerPatch |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
Indicates whether task is running per patch or not. |
JPP_RollbackFlag |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
Indicates whether or not rollback is enabled for the workflow task. (overrides OH_RollbackFlag) |
JPP_RunPerTarget |
smallint |
NUMBER(38,0) |
smallint |
smallint |
true |
Indicates how to run the workflow per deployment target. 1 = serial, 2 = parallel |