Remote Task Manager Attributes

This overview includes the attributes of this object type and describes their functions and allowed values as well as indications as to how to modify them.

General Page

Field

Attribute

Value

Access Via:

Title

OBJECT_TITLE

User-defined,
limited to 255 characters.

GET_ATT,
:PUT_ATT (Pre-Process, Process),
predefined variable

Created

USER_CREATED

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

DATE_CREATED

Time stamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT

Modified

USER_MODIFIED

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

DATE_MODIFIED

Time stamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT

MODIFY_COUNT

The number of object modifications.

GET_ATT

Last Used

 

LAST_USER

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

LAST_DATE

The time stamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT,
predefined variable

USAGE_COUNT

Number of object usages

GET_ATT,
predefined variable

Archive key 1

ARCHIVE_KEY1

User-defined,
limited to 60 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Archive key 2

ARCHIVE_KEY2

User-defined,
limited to 20 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Process Tab

Field

Attribute

Value

Access Via:

The string in the Process tab of the job should be changed.

SCRIPT

 

Change Program

Output Scan Page

Field

Attribute

Value

Access Via:

Action - Output filter PPF_FILTER The name of a Filter object,
limited to 200 characters.
Change Program
Action - Execute PPF_EXECUTE The name of an executable object,
limited to 200 characters.
Change Program
Pass down to dynamic children PPF_INHERITANCE "Y" - Yes
"N" - No
"C" - Children only
Change Program
Override host for FileScan (optional) - Host FSC_HOST The name of an agent,
limited to 32 characters.
GET_ATT,
:PUT_ATT (Pre-Process, Process),
Change Program,
predefined variable
Override host for FileScan (optional) - Login FSC_LOGIN The name of a Login object,
limited to 200 characters
GET_ATT,
:PUT_ATT (Pre-Process, Process),
Change Program,
predefined variable

Remote Task Manager Attributes Not on a Tab

Field

Attribute

Value

Access Via:

Object name

OBJECT_NAME

User-defined,
limited to 200 characters.

Change Program

Mode UserInterface

DCMODUS

"Y" - UserInterface is active
"N" - No UserInterface is active

GET_ATT