Event Object Attributes
The following tables list the attributes that apply to all event object types and describe their functions, allowed values and ways of modification.
Attributes for All Event Type
The attributes of an event can only be written in the Process Pages if the event is activated. If you try to read or write an attribute that does not belong to the particular event type causes the script processing to abort.
General Page
Field |
Attribute |
Value |
Access Via: |
---|---|---|---|
Title |
OBJECT_TITLE |
User-defined, |
GET_ATT, |
Created by |
USER_CREATED |
The name of the User object, |
GET_ATT, |
DATE_CREATED |
Time stamp in the format "YYYY-MM-DD HH:MM:SS" |
GET_ATT |
|
Modified by |
USER_MODIFIED |
The name of the User object, |
GET_ATT, |
DATE_MODIFIED |
Time stamp in the format "YYYY-MM-DD HH:MM:SS" |
GET_ATT |
|
MODIFY_COUNT |
The number of object modifications. |
GET_ATT |
|
Last executed by
|
LAST_USER |
The name of the User object, |
GET_ATT, |
LAST_DATE |
The time stamp in the format "YYYY-MM-DD HH:MM:SS" |
GET_ATT, |
|
USAGE_COUNT |
Number of object usages |
GET_ATT, |
|
Archive Key 1 |
ARCHIVE_KEY1 |
User-defined, |
GET_ATT, |
Archive Key 2 |
ARCHIVE_KEY2 |
User-defined, |
GET_ATT, |
Sync Page
Field | Description | Attribute | Access Via: |
---|---|---|---|
Assigned Sync object | SYNC_OBJECT | The name of a Sync object, a maximum of 20 characters must not be exceeded. |
Change Program |
Attributes Page
Field |
Attribute |
Value |
Access Via: |
---|---|---|---|
Queue | QUEUE | The name of a queue, limited to 200 characters. |
GET_ATT, :PUT_ATT, Change Program, predefined variable |
Group | GROUP | The name of a group, limited to 200 characters. " " - for immediate start |
GET_ATT, :PUT_ATT, Change Program, predefined variable |
Int. Account |
INT_ACCOUNT, INT_ACC, K |
User-defined, |
GET_ATT, |
Automation Engine priority |
UC4_PRIORITY |
User-defined, |
GET_ATT, |
TimeZone |
TIMEZONE |
User-defined |
GET_ATT, |
Generate at runtime |
GEN_AT_RUNTIME |
"Y" - Yes, "N" - No |
GET_ATT |
Parallel running tasks - Max number |
MAX_PARALLEL_TASKS |
User-defined, |
GET_ATT, |
Parallel running tasks - Else |
MAX_PARALLEL_ELSE |
"WAIT" - The event waits until processing is possible. |
GET_ATT, |
Automatically deactivate when finished |
AUTO_DEACT |
"NEVER" - Never deactivate automatically. |
GET_ATT, |
Error-free status (for After an error-free restart) |
AUTO_DEACT_ERROR_FREE |
Task status limited to 20 characters |
GET_ATT, |
Time delay minutes (for Always) |
AUTO_DEACT_DELAY |
User-defined, |
GET_ATT, |
Runtime Page
Field |
Attribute |
Value |
Access Via: |
---|---|---|---|
Return code <= |
MAX_RETCODE |
User-defined, |
GET_ATT, |
Process Page
Field |
Attribute |
Value |
Access Via: |
---|---|---|---|
The string in the Process tab of the event should be changed. |
PSCRIPT |
|
Change Program |
Event Process Page
Field |
Attribute |
Value |
Access Via: |
---|---|---|---|
Modification of the Event Process page of events. | SCRIPT |
Change Program |
Event Attributes not in a Tab
Field |
Attribute |
Value |
Access Via: |
---|---|---|---|
Event type |
EVENT_TYPE, EVENT_TYP |
"CN" - Console event, |
GET_ATT, |
Object name |
OBJECT_NAME |
User-defined, |
Change Program |
Automic Web Interface Mode |
DCMODUS |
"Y" - The Automic Web Interface is active |
GET_ATT |
See also: