Job Group Attributes

The following overview includes the attributes of a Group object and describes their functions, allowed values and ways of modification.

Predefined variables may be used in scripts, and script variables may be set to attributes retrieved via predefined variables.

General Page

Field

Attribute

Value

Access Via:

Title

OBJECT_TITLE

User-defined,
limited to 255 characters.

GET_ATT,
:PUT_ATT (Pre-Process, Process),
predefined variable

Created by

USER_CREATED

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

DATE_CREATED

Time stamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT

Modified by

USER_MODIFIED

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

DATE_MODIFIED

Time stamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT

MODIFY_COUNT

The number of object modifications.

GET_ATT

Last executed by

 

LAST_USER

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

LAST_DATE

The time stamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT,
predefined variable

USAGE_COUNT

Number of object usages

GET_ATT,
predefined variable

Archive Key 1

ARCHIVE_KEY1

User-defined,
limited to 60 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Archive Key 2

ARCHIVE_KEY2

User-defined,
limited to 20 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Sync Page

Field Description Attribute Access Via:
Assigned Sync object SYNC_OBJECT The name of a Sync object,
a maximum of 20 characters must not be exceeded.
Change Program

Attributes Page

Field

Attribute

Value

Access Via

Max. parallel running tasks

GR_MAX_PAR_JOBS

User-defined,
any value between "0" and "999".

When reading the attribute, the system returns a 16-digit value with leading zeros.

GET_ATT,
:PUT_ATT

Queue QUEUE Name of a queue,
maximum 200 characters
GET_ATT,
:PUT_ATT (process)
Change Program
Children queue CHILD_QUEUE

The name of the Queue object for the group's tasks,
limited to 200 characters.

GET_ATT,
:PUT_ATT,
Change Program

TimeZone

TIMEZONE

User-defined
a maximum of 8 characters must not be exceeded.

GET_ATT,
:PUT_ATT,
Change Program

Generate at runtime

GEN_AT_RUNTIME

"Y" - Generation at runtime.
"N" - Generation at activation time.

GET_ATT

Automatically deactivate when finished

AUTO_DEACT

"NEVER" - Never deactivate automatically.
"ENDED_ERROR_FREE" - In the case of error-free processing, deactivate automatically.
"RESTART_ERROR_FREE" - In the case of an error-free restart, deactivate automatically. 
"ALWAYS" - Always deactivate automatically.

GET_ATT,
:PUT_ATT

Error-free status (for After an error-free restart)

AUTO_DEACT_DELAY

User-defined,
any value between "0" and "99".

GET_ATT,
:PUT_ATT

Time delay minutes (for Always)

AUTO_DEACT_ERROR_FREE

Task status
limited to 20 characters

See System Return Codes of Executable Objects.

GET_ATT,
:PUT_ATT

Runtime Page

Field

Attribute

Value

Access Via:

Return code <=

MAX_RETCODE

User-defined,
limited to 11 numbers.

GET_ATT,
:PUT_ATT (Pre-Process, Process)

Process Page

Field

Attribute

Value

Access Via:

The string in the Process tab of the job should be changed.

SCRIPT

 

Change Program

Group Attributes Not on a Page

Field

Attribute

Value

Access Via:

Object name

OBJECT_NAME

User-defined,
limited to 200 characters.

Change Program

Automic Web Interface Mode

DCMODUS

"Y" - The Automic Web Interface is active
"N" - No Automic Web Interface is active

GET_ATT

See also: