Script Attributes
This overview includes the attributes of this object type and describes their functions and allowed values as well as indications as to how to modify them.
You can use predefined variables in Scripts. Script variables can be set to attributes retrieved via predefined variables
General Page
Field |
Attribute |
Value |
Access Via: |
---|---|---|---|
Title |
OBJECT_TITLE |
User-defined, |
GET_ATT, |
Created by |
USER_CREATED |
The name of the User object, |
GET_ATT, |
DATE_CREATED |
Time stamp in the format "YYYY-MM-DD HH:MM:SS" |
GET_ATT |
|
Modified by |
USER_MODIFIED |
The name of the User object, |
GET_ATT, |
DATE_MODIFIED |
Time stamp in the format "YYYY-MM-DD HH:MM:SS" |
GET_ATT |
|
MODIFY_COUNT |
The number of object modifications. |
GET_ATT |
|
Last executed by
|
LAST_USER |
The name of the User object, |
GET_ATT, |
LAST_DATE |
The time stamp in the format "YYYY-MM-DD HH:MM:SS" |
GET_ATT, |
|
USAGE_COUNT |
Number of object usages |
GET_ATT, |
|
Archive Key 1 |
ARCHIVE_KEY1 |
User-defined, |
GET_ATT, |
Archive Key 2 |
ARCHIVE_KEY2 |
User-defined, |
GET_ATT, |
Sync Page
Field | Description | Attribute | Access Via: |
---|---|---|---|
Assigned Sync object | SYNC_OBJECT | The name of a Sync object, a maximum of 20 characters must not be exceeded. |
Change Program |
Attributes Page
Description |
Attribute |
Value |
Access Via |
Queue | QUEUE | Name of a queue, maximum 200 characters |
GET_ATT, :PUT_ATT, Change Program, predefined variable |
Group | GROUP | Name of a group, maximum 200 characters " " - for immediate start |
GET_ATT, :PUT_ATT, Change Program, predefined variable |
Int. Account |
INT_ACCOUNT, INT_ACC, K |
User-defined, |
GET_ATT, |
Automation Engine priority |
UC4_PRIORITY |
User-defined, |
GET_ATT, |
TimeZone |
TIMEZONE |
Name of a TimeZone object |
GET_ATT, |
Generate at runtime |
GEN_AT_RUNTIME |
"Y" - Generation at runtime |
GET_ATT |
Tasks running parallel - Max. number |
MAX_PARALLEL_TASKS |
User-defined, |
GET_ATT, |
Tasks running parallel - Else |
MAX_PARALLEL_ELSE |
"WAIT" - Script waits until processing is possible |
GET_ATT, |
Automatically deactivate when finished |
AUTO_DEACT |
"NEVER" - Never deactivate automatically. |
GET_ATT, |
Time delay minutes (for Always) |
AUTO_DEACT_DELAY |
User-defined, |
GET_ATT, |
Error-free status (for After an error-free restart) |
AUTO_DEACT_ERROR_FREE |
System Return Codes of Executable Objects limited to 20 characters |
GET_ATT, |
Runtime Page
Field |
Attribute |
Value |
Access Via: |
---|---|---|---|
Return code <= |
MAX_RETCODE |
User-defined, |
GET_ATT, |
Process Page
Field |
Attribute |
Value |
Access Via: |
---|---|---|---|
String in the script of the Script object which should be changed |
SCRIPT |
|
Change Program |