:SHUTDOWN
            The script statement :SHUTDOWN ends an Automation Engine system including all its work processes and communication processes. To end only particular work and communication processes, or the agent, see :TERMINATE.
To be able to use this script statement, you require the C (cancel) right for server processes (SERV type). For details, see e Managing Authorizations at Object Level
Syntax
:SHUTDOWN UC4
| 
                         Syntax  | 
                    
                         Description/Format  | 
                
|---|---|
| 
                         UC4  | 
                    
                         Specific term that must be used to end your Automation Engine system.  | 
                
Example
The following example ends the AE system when the current time is later than 20:00 (8:00 PM):
:IF SYS_TIME() > "200000"
:   SHUTDOWN UC4
:ENDIF
            
See also:
| Script element | Description | 
|---|---|
| Disconnects a connection to the AE system. | |
| :TERMINATE | Ends an agent, a work or communication process. | 
Script Elements - System Conditions and Settings
About Scripts
Script Elements - Alphabetical Listing
Script Elements - Ordered by Function