Job Group Attributes

The following overview includes the attributes of a Group object and describes their functions, allowed values and ways of modification.

Note: Predefined variables may be used in scripts, and script variables may be set to attributes retrieved via predefined variables.

General Page

Field

Attribute

Value

Access Via:

Title

OBJECT_TITLE

User-defined,
limited to 255 characters.

GET_ATT,
:PUT_ATT (Pre-Process, Process),
predefined variable

Active OH_Inactive   Change Program

Created

USER_CREATED

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

DATE_CREATED

Timestamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT

Modified

USER_MODIFIED

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

DATE_MODIFIED

Timestamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT

MODIFY_COUNT

The number of object modifications.

GET_ATT

Last Executed

 

LAST_USER

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

LAST_DATE

The timestamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT,
predefined variable

USAGE_COUNT

Number of object usages

GET_ATT,
predefined variable

Archive key 1

ARCHIVE_KEY1

User-defined,
limited to 60 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Archive key 2

ARCHIVE_KEY2

User-defined,
limited to 20 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Int. Account

INT_ACCOUNT, INT_ACC, K

User-defined,
limited to 16 characters.

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Sync Page

Field Description Attribute Access Via:
Assigned Sync object SYNC_OBJECT The name of a Sync object,
a maximum of 20 characters must not be exceeded.
Change Program

Attributes Page

Field

Attribute

Value

Access Via

Max. parallel running tasks

GR_MAX_PAR_JOBS

User-defined,
any value between "0" and "999".

When reading the attribute, the system returns a 16-digit value with leading zeros.

GET_ATT,
:PUT_ATT

Queue QUEUE Name of a queue,
maximum 200 characters
GET_ATT,
:PUT_ATT (process)
Change Program
Children queue CHILD_QUEUE

The name of the Queue object for the group's tasks,
limited to 200 characters.

GET_ATT,
:PUT_ATT,
Change Program

TimeZone

TIMEZONE

User-defined
a maximum of 8 characters must not be exceeded.

GET_ATT,
:PUT_ATT,
Change Program

Generate at runtime

GEN_AT_RUNTIME

"Y" - Generation at runtime.
"N" - Generation at activation time.

GET_ATT

Automatically deactivate when finished

AUTO_DEACT

"NEVER" - Never deactivate automatically.
"ENDED_ERROR_FREE" - In the case of error-free processing, deactivate automatically.
"RESTART_ERROR_FREE" - In the case of an error-free restart, deactivate automatically. 
"ALWAYS" - Always deactivate automatically.

GET_ATT,
:PUT_ATT

Error-free status (for After an error-free restart)

AUTO_DEACT_DELAY

User-defined,
any value between "0" and "99".

GET_ATT,
:PUT_ATT

Time delay minutes (for Always)

AUTO_DEACT_ERROR_FREE

Task status
limited to 20 characters

See System Return Codes of Executable Objects.

GET_ATT,
:PUT_ATT

Runtime Page

Field

Attribute

Value

Access Via:

Return code <=

MAX_RETCODE

User-defined,
limited to 11 numbers.

GET_ATT,
:PUT_ATT (Pre-Process, Process)

Note: The status of the file transfer does not affect its return code. If, for any reason, a file transfer fails, the return code is still 0.

Process Page

Field

Attribute

Value

Access Via:

The string in the Process tab of the job should be changed.

SCRIPT

 

Change Program

Group Attributes Not on a Page

Field

Attribute

Value

Access Via:

Object name

OBJECT_NAME

User-defined,
limited to 200 characters.

Change Program

Automic Web Interface Mode

DCMODUS

"Y" - The Automic Web Interface is active
"N" - No Automic Web Interface is active

GET_ATT

See also: