Schedule Attributes

This overview includes the attributes of this object type and describes their functions and allowed values as well as indications as to how to modify them.

General Page

Field

Attribute

Value

Access Via:

Title

OBJECT_TITLE

User-defined,
limited to 255 characters.

GET_ATT,
:PUT_ATT (Pre-Process, Process),
predefined variable

Active OH_Inactive   Change Program

Created

USER_CREATED

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

DATE_CREATED

Timestamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT

Modified

USER_MODIFIED

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

DATE_MODIFIED

Timestamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT

MODIFY_COUNT

The number of object modifications.

GET_ATT

Last Executed

 

LAST_USER

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

LAST_DATE

The timestamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT,
predefined variable

USAGE_COUNT

Number of object usages

GET_ATT,
predefined variable

Archive key 1

ARCHIVE_KEY1

User-defined,
limited to 60 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Archive key 2

ARCHIVE_KEY2

User-defined,
limited to 20 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Int. Account

INT_ACCOUNT, INT_ACC, K

User-defined,
limited to 16 characters.

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Sync Page

Field Description Attribute Access Via:
Assigned Sync object SYNC_OBJECT The name of a Sync object,
a maximum of 20 characters must not be exceeded.
Change Program

Attributes Page

Field

Attribute

Value

Accesses Via:

Queue QUEUE The name of a Queue object,
maximum 200 characters
GET_ATT,
:PUT_ATT,
Change Program,
predefined variable
Children queue CHILD_QUEUE

The name of the Queue object for the Schedule object's task,
maximum 200 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable
Group GROUP The name of a Group object,
maximum 200 characters
" " - for immediate start
GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Int. account

INT_ACCOUNT, INT_ACC, K

User-defined,
maximum 16 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Period

JSCH_PERIOD

Any value between "0" and "99"

GET_ATT

Period turn around

JSCH_PERIOD_TA

Time format HH:MM

GET_ATT

Automation Engine priority

UC4_PRIORITY

User-defined,
any value between "0" and "255"

GET_ATT,
:PUT_ATT,
predefined variable

TimeZone

TIMEZONE

The name of a TimeZone object
maximum 8 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Generate at runtime

GEN_AT_RUNTIME

"Y" - Generation at runtime
"N" - Generation at activation time

GET_ATT

Tasks running parallel - Max. number

MAX_PARALLEL_TASKS

User-defined,
Value between "0" and "99999"

GET_ATT,
:PUT_ATT,
predefined variable

Tasks running parallel - Else

MAX_PARALLEL_ELSE

"WAIT" - The Schedule object waits until processing is possible.
"ABEND" - Schedule object disrupted.

GET_ATT,
:PUT_ATT

Schedule Page

Column

Attribute

Value

Accesses Via:

Calendar CALENDAR The name of a calendar,
maximum 200 characters
Change Program
Keyword CALENDAR_KEYWORD The name of a calendar event,
maximum 200 characters
Change Program
Name TASK_NAME The name of an executable object,
maximum 200 characters
Change Program

Runtime Page

Field

Attribute

Value

Access Via:

Return code <=

MAX_RETCODE

User-defined,
limited to 11 numbers.

GET_ATT,
:PUT_ATT (Pre-Process, Process)

Note: The status of the file transfer does not affect its return code. If, for any reason, a file transfer fails, the return code is still 0.

Process Page

Field

Attribute

Value

Access Via:

String in the script of the Schedule object that should be changed

SCRIPT

 

Change Program

Schedule Attributes Not on a Page

Field

Attribute

Value

Access Via:

Object name

OBJECT_NAME

User-defined,
limited to 200 characters.

Change Program

Automic Web Interface Mode

DCMODUS

"Y" - The Automic Web Interface is active
"N" - No Automic Web Interface is active

GET_ATT

See also: