Script Attributes

This overview includes the attributes of this object type and describes their functions and allowed values as well as indications as to how to modify them.

You can use predefined variables in Scripts. Script variables can be set to attributes retrieved via predefined variables

General Page

Field

Attribute

Value

Access Via:

Title

OBJECT_TITLE

User-defined,
limited to 255 characters.

GET_ATT,
:PUT_ATT (Pre-Process, Process),
predefined variable

Active OH_Inactive   Change Program

Created

USER_CREATED

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

DATE_CREATED

Timestamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT

Modified

USER_MODIFIED

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

DATE_MODIFIED

Timestamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT

MODIFY_COUNT

The number of object modifications.

GET_ATT

Last Executed

 

LAST_USER

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

LAST_DATE

The timestamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT,
predefined variable

USAGE_COUNT

Number of object usages

GET_ATT,
predefined variable

Archive key 1

ARCHIVE_KEY1

User-defined,
limited to 60 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Archive key 2

ARCHIVE_KEY2

User-defined,
limited to 20 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Int. Account

INT_ACCOUNT, INT_ACC, K

User-defined,
limited to 16 characters.

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Sync Page

Field Description Attribute Access Via:
Assigned Sync object SYNC_OBJECT The name of a Sync object,
a maximum of 20 characters must not be exceeded.
Change Program

Attributes Page

Description

Attribute

Value

Access Via

Queue QUEUE Name of a queue,
maximum 200 characters
GET_ATT,
:PUT_ATT,
Change Program,
predefined variable
Group GROUP Name of a group,
maximum 200 characters
" " - for immediate start
GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Int. Account

INT_ACCOUNT, INT_ACC, K

User-defined,
maximum 16 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Automation Engine priority

UC4_PRIORITY

User-defined,
Value between "0" and "255"

GET_ATT,
:PUT_ATT,
predefined variable

TimeZone

TIMEZONE

Name of a TimeZone object
maximum 8 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Generate at runtime

GEN_AT_RUNTIME

"Y" - Generation at runtime
"N" - Generation at activation time

GET_ATT

Tasks running parallel - Max. number

MAX_PARALLEL_TASKS

User-defined,
Value between "0" and "99999"

GET_ATT,
:PUT_ATT,
predefined variable

Tasks running parallel - Else

MAX_PARALLEL_ELSE

"WAIT" - Script waits until processing is possible
"ABEND" - Script is interrupted 

GET_ATT,
:PUT_ATT

Automatically deactivate when finished

AUTO_DEACT

"NEVER" - Never deactivate automatically.
"ENDED_ERROR_FREE" - In the case of error-free processing, deactivate automatically.
"RESTART_ERROR_FREE" - In the case of an error-free restart, deactivate automatically. 
"ALWAYS" - Always deactivate automatically.

GET_ATT,
:PUT_ATT

Time delay minutes (for Always)

AUTO_DEACT_DELAY

User-defined,
any value between "0" and "99".

GET_ATT,
:PUT_ATT

Error-free status (for After an error-free restart)

AUTO_DEACT_ERROR_FREE

System Return Codes of Executable Objects limited to 20 characters

GET_ATT,
:PUT_ATT

Runtime Page

Field

Attribute

Value

Access Via:

Return code <=

MAX_RETCODE

User-defined,
limited to 11 numbers.

GET_ATT,
:PUT_ATT (Pre-Process, Process)

Note: The status of the file transfer does not affect its return code. If, for any reason, a file transfer fails, the return code is still 0.

Process Page

Field

Attribute

Value

Access Via:

String in the script of the Script object which should be changed

SCRIPT

 

Change Program

See also: