Job Group Attributes
The following overview includes the attributes of Job Group objects and describes their functions, allowed values and ways of modification.
Predefined variables may be used in scripts, and script variables may be set to attributes retrieved via predefined variables.
General Page
Title
OBJECT_TITLE
Value: User-defined
Length: 255 characters
Access through: GET_ATT, :PUT_ATT (Pre-Process, Process), predefined variable
Active
OH_Inactive
Access through: Change Program
Created by
USER_CREATED
Value: Name of the User object
Length: Max. 200 characters
Access through: GET_ATT, predefined variable
DATE_CREATED
Value: Timestamp
Format: YYYY-MM-DD HH:MM:SS. If not available, 0000-00-00 00:00:00
Access through: GET_ATT
Modified by
USER_MODIFIED
Value: Name of the User object
Length: 200 characters
Access through: GET_ATT, predefined variable
DATE_MODIFIED
Value: Timestamp
Format: YYYY-MM-DD HH:MM:SS. If not available, 0000-00-00 00:00:00
Access through: GET_ATT
MODIFY_COUNT
Value: Number of object modifications
Access through:GET_ATT
Last Executed
LAST_USER
Value: Name of the User object
Length: 200 characters
Access through: GET_ATT, predefined variable
LAST_DATE
Value: Timestamp
Format: YYYY-MM-DD HH:MM:SS. If not available, 0000-00-00 00:00:00
Access through: GET_ATT, predefined variable
USAGE_COUNT
Value: Number of object usages
Access through: GET_ATT, predefined variable
Archive Key 1
ARCHIVE_KEY1
Value: User-defined
Length: 60 characters
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
Archive Key 1
ARCHIVE_KEY2
Value: User-defined
Length: 20 characters
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
Int. Account
INT_ACCOUNT, INT_ACC, K
Value: User-defined
Length:16 characters
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
Sync Page
Sync Object
SYNC_OBJECT
Value: Name of the Sync object
Length: 20 characters
Access via: Change Program
Attributes Page
Max. parallel running tasks
GR_MAX_PAR_JOBS
Value: User-defined
Length: A vaue between 0 and 999. When reading the attribute, the system returns a 16-digit value with leading zeros.
Access through: GET_ATT, :PUT_ATT
Queue
QUEUE
Value: Name of the Queue
Length: Max. 200 characters
Access through: GET_ATT, :PUT_ATT (process), Change Program
Children queue
CHILD_QUEUE
Value: Name of the Queue on which the task in the Group runs
Length: Max. 200 characters
Access through: GET_ATT, :PUT_ATT, Change Program
TimeZone
TIMEZONE
Value: User-defined
Length: Max. 8 characters
Access through: GET_ATT, :PUT_ATT, Change Program
Generate Task at: Runtime
GEN_AT_RUNTIME
Value: Y / N
Access through: GET_ATT
Automatically deactivate when finished
Value: AUTO_DEACT
Length:
- NEVER (never deactivate automatically)
- ENDED_ERROR_FREE (in case of error free processing, deactivate automatically)
- RESTART_ERROR_FREE (in case of error-free restart, deactivate automatically)
- ALWAYS (Always deactivate automatically)
Access through: GET_ATT, :PUT_ATT
Error-free status
After an error-free restart
Value: AUTO_DEACT_DELAY
Length: A value between 0 and 99
Access through: GET_ATT, :PUT_ATT
Time delay minutes (for Always)
AUTO_DEACT_ERROR_FREE
Value: Task status (System Return Codes of Executable Objects)
Length: Max. 20 characters
Access through: GET_ATT, :PUT_ATT
Runtime Page
Return code <=
MAX_RETCODE
Value: User-defined
Length: 10 characters
Access via: GET_ATT, :PUT_ATT (Pre-Process, Process)
Note: The status of the file transfer does not affect its return code. If, for any reason, a file transfer fails, the return code is still 0.
Process Page
Code on the Process Page
Changes the code on the Process page
Access through: Change Program
Group Attributes Not on a Page
Object Name
OBJECT_NAME
Value: User-defined
Length: Max. 200 characters
Access through: Change Program
AWI Mode
DCMODUS
Value: Y / N
Access through: GET_ATT
See also: