R3_SET_STATUS_ATTR
The R3_SET_STATUS_ATTR script element sets a status attribute in the SAP monitor architecture. Use R3_SET_STATUS_ATTR to change an existing log attribute.If it does not yet exist, this script element creates one including the corresponding message.
Transaction: RZ20
Interface: XMW
Syntax
R3_SET_STATUS_ATTR
NODE=...
,MESSAGE=...
[,VAR1=...]
[,VAR2=...]
[">,VAR3=...]
[,VAR4=...]
[,COL_METHOD=...]
[,AN_METHOD=...]
[,AU_METHOD=...]
[,CAUSE_ALERT=...]
[,COLOR=...]
Parameters
-
R3_SET_STATUS_ATTR
Sets a status attribute in the SAP monitor architecture -
NODE=
Name of the node.
Format: script literal
This parameter describes a complete path. The individual parts are separated by a slash (/). The path always starts with a context node that can be followed by a sum node, an object node and an attribute node.
Note: Context, object and attribute nodes must only be used once in the path. Sum nodes can be used several times.Example 1
UC4/TestNode/PerfAttributUC4
- UC4
Context name - TestNode
Object node - PerfAttributUC4
Attribute node
Example 2
UC4/Summary1/Summary2/TestNode/PerfAttributUC4
- UC4
Context name - Summary1
Sum node - Summary2
Sum node - TestNode
Object node - PerfAttributUC4
Attribute node
- UC4
-
MESSAGE=
ID and number of the SAP T100 message, separated by a blank)
Format: script literal
Note: Use 00 398 to have only variable contents displayed. -
VAR1=
(Optional) Message variable 1
Format: script literal -
VAR2=
(Optional) Message variable 2
Format: script literal -
VAR3=
(Optional) Message variable 3
Format: script literal -
VAR4=
(Optional) Message variable 4
Format: script literal -
COL_METHOD=
(Optional) Defines the data collection method of the node
Format: script literal -
AN_METHOD=
(Optional) Defines the analysis method of the node
Format: script literal -
AU_METHOD=
(Optional) Defines the auto-reaction method of the node
Format: script literal -
CAUSE_ALERT=
(Optional) Determines when an alarm should be triggered
Format: script literal
Allowed values:-
ALWAYS (default)
Always triggers an alarm -
VALUE_CHG
Triggers an alarm when the value has changed -
MSG_CHG
Triggers an alarm when the message has changes -
NEVER
Never triggers an alarm
-
ALWAYS (default)
- COLOR=
(Optional) Color
Format: script literal
Allowed values:- AL_VAL_GREEN (default)
Green - AL_VAL_YELLOW
Yellow - AL_VAL_RED
Red
- AL_VAL_GREEN (default)
Example
Executing the following example creates the UC4 context node UC4, the Test object node and the status attribute including the message SY 019.
R3_SET_STATUS_ATTR NODE="UC4/Test/StatusAttribute",MESSAGE="SY 019"
See also:
seealso