Event Object Attributes
Here you get the overview of the list of attributes that apply to all Event object types. All attributes and their corresponding definition are gathered by object definition page in the UI (General page, Sync page, and so on) so that you can access all the relevant ones to a given page at once.
The attributes of an Event can only be written on the Process Pages if the event is activated.
Important! Reading or writing an attribute that does not belong to the particular Event type causes the script processing to abort.
General Page
Title
OBJECT_TITLE
Value: User-defined
Length: 512 characters
Access through: GET_ATT, :PUT_ATT (Pre-Process, Process), predefined variable
Active
OH_Inactive
Access through: Change Program
Created by
USER_CREATED
Value: Name of the User object
Length: Max. 200 characters
Access through: GET_ATT, predefined variable
DATE_CREATED
Value: Timestamp
Format: YYYY-MM-DD HH:MM:SS. If not available, 0000-00-00 00:00:00
Access through: GET_ATT
Modified by
USER_MODIFIED
Value: Name of the User object
Length: 200 characters
Access through: GET_ATT, predefined variable
DATE_MODIFIED
Value: Timestamp
Format: YYYY-MM-DD HH:MM:SS. If not available, 0000-00-00 00:00:00
Access through: GET_ATT
MODIFY_COUNT
Value: Number of object modifications
Access through :GET_ATT
Last Executed
LAST_USER
Value: Name of the User object
Length: 200 characters
Access through: GET_ATT, predefined variable
LAST_DATE
Value: Timestamp
Format: YYYY-MM-DD HH:MM:SS. If not available, 0000-00-00 00:00:00
Access through: GET_ATT, predefined variable
USAGE_COUNT
Value: Number of object usages
Access through: GET_ATT, predefined variable
Archive Key 1
ARCHIVE_KEY1
Value: User-defined
Length: 512 characters
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
Archive Key 2
ARCHIVE_KEY2
Value: User-defined
Length: 512 characters
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
Int. Account
INT_ACCOUNT, INT_ACC, K
Value: User-defined
Length:16 characters
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
Sync Page
Sync Object
SYNC_OBJECT
Value: Name of the Sync object
Length: 20 characters
Access via: Change Program
Attributes Page
Queue
QUEUE
Value: Name of a Queue
Length: Max. 200 characters
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
Group
GROUP
Value: Name of a Group
Length: Max. 200 characters
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
Automation Engine priority
UC4_PRIORITY
Value: User-defined
Length: Max. 16 characters
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
TimeZone
TIMEZONE
Value: Nmae of a Time Zone object
Length: Max. 8 characters
Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable
Generate Task at: Runtime
GEN_AT_RUNTIME
Value: Y / N
Access through: GET_ATT
Tasks running parallel - Max. number
MAX_PARALLEL_TASKS
Value: User-defined
Length: Any value between 0 and 99999
Access through: GET_ATT, :PUT_ATT, predefined variable
Tasks running parallel - Else
MAX_PARALLEL_ELSE
Value: WAIT (Script waits until processing is possible) / ABEND
Access through: GET_ATT, :PUT_ATT
Automatically deactivate when finished
AUTO_DEACT
Value:
- NEVER:
- ENDED_ERROR_FREE
- RESTART_ERROR_FREE
- ALWAYS
Access through: GET_ATT, :PUT_ATT
Time delay minutes (for Always)
AUTO_DEACT_DELAY
Value: User-defined
Length: Any value between 0 and 99
Access through: GET_ATT, :PUT_ATT
Error-free status (for After an error-free restart)
AUTO_DEACT_ERROR_FREE
Value: System Return Codes of Executable Objects limited to 20 characters
Access through: GET_ATT, :PUT_ATT
Runtime Page
Return code <=
MAX_RETCODE
Value: User-defined
Length: 10 characters
Access via: GET_ATT, :PUT_ATT (Pre-Process, Process)
Note: The status of the file transfer does not affect its return code. If, for any reason, a file transfer fails, the return code is still 0.
Process Page
Modifies the string on the Process page
PSCRIPT
Access through: Change Program
Event Process Page
SCRIPT
Modifies the scrip on the Event Process page
Access through: Change Program
Event Attributes not on a Page
Event type
EVENT_TYPE, EVENT_TYP
Value:
- CN - Console event
- DS - Database event with time
- DT - Database event with interval
- FA - File System event with automatic monitoring
- FS - File System event with time
- FT - File System event with interval
- TS - Time event with time
- TT - Time event with interval
Access through: GET_ATT, predefined variable
Object name
OBJECT_NAME
Value: User-defined
Length: Max. 200 characters
Access through: Change Program
AWI mode
DCMODUS
Value: Y / N
Access through: GET_ATT
See also: