:BEGINREAD... :ENDREAD
Use the :BEGINREAD and :ENDREAD script statements to define the start and end of the contents of a dialog. Include any number of elements between the :BEGINREAD and :ENDREAD statements to define texts and query users in the dialog.
Write :READ statements between the two commands to define user queries. The number of :READ statements determines the size of the dialog. The parameters that you specify in the :READ statements also appearance of the dialog, and the functions of the input fields. Use :PRINT statements to provide information or instructions in the dialog.
Syntax
:BEGINREAD [Label[,F]]
Statements
:ENDREAD
Parameters
-
:BEGINREAD
Defines the beginning of the dialog contents -
Label
(Optional) Name of the dialog
Format: script literal, script variable or script function
Default value: name of the object -
F
(Optional) Formats the text in the dialog so that all letters are the same width
Tip: this parameter is helpful for aligning columns. -
Statements
Script statements that define the contents of the dialog -
:ENDREAD
Defines the end of the dialog contents
Notes:
- You can include any number of :READ and :PRINT statements between :BEGINREAD and :ENDREAD.
- This script statement causes all the open transactions of the script to be written to the AE database.
Important! The dialog is not displayed if the task, or the Workflow that the task runs in, is configured to be generated at runtime. When the dialog is not displayed, default values are used for the :READ statements. If the default values result in invalid responses, script generation is canceled.
More information:
- Script Processing
- Executing Objects: Generating Task at Activation Time vs Generating Task at Runtime
Example
The following example creates a dialog titled Log on, which requests the user to enter their department and name:
:BEGINREAD "Log on"
:READ &DEP#, "08", "Please enter your department",, M
:READ &NAME#, "08", "Please enter your name",, M
:ENDREAD