Configuring System Objects
The following guide describes the specific configuration of an Automation Engine's system objects that are required for the RA Hyperion FDMEE Agent.
- Create and configure an RA Hyperion FDMEE Agent solution Agent object in your Automation Engine's system client 0000.
- Start the Agent.
- Create and configure one or more RA Hyperion FDMEE Agent Connection objects in non-system numbered clients.
Agent Object
-
Create a new HYPERIONFDMEE AGENT object (preferably in the HOST folder).
Important !Note that the object name must comply with the Agent name that is used in the INI file.
- Save the Agent object.
The traffic light symbol in the tab's lower bar is shown in green if the Agent is active.
There is nothing to define on the RA Hyperion FDMEE Agent solution Agent object's HyperionFDMEE tab.
Start the Agent using the following command:
java -jar <Path to the Agent's BIN directory>/ucxjcitx.jar disable_cache
You can also start the Agent via the Service Manager. For more information, see your Automation Engine documentation.
Connection Object
The Connection object(s) defined the connection to the Hyperion FDMEE system.
- Create a new RA Hyperion FDMEE Agent Connection object (new object: CONN -> HYPERIONFDMEE) and open it.
- User
- Password
- AIF Url
- Application root folder
- Save the Connection object.
The Hyperion FDMEE user
The Hyperion FDMEE password
URL of AIF webservice
Default value: http://localhost:9000/aif
The directory of the application root folder. i.e. C:\Oracle\FDMEE_App_Root
The Login field on the Attributes