AJPP_AH_Idnr |
int |
NUMBER(38,0) |
int |
false |
reference to the archive header (AH) |
AJPP_Lnr |
smallint |
NUMBER(38,0) |
smallint |
false |
ascending number of the jobplan process |
AJPP_Status |
int |
NUMBER(38,0) |
int |
true |
state of the process line of the jobplan (blocking ...) |
AJPP_JobStatus |
int |
NUMBER(38,0) |
int |
true |
state of the process line from the job execution (ok,ended,abended) |
AJPP_Substatus |
char (1) |
CHAR (1 CHAR) |
char(1) |
true |
sub state (H, A) if precondition (WHEN) is not true |
AJPP_OType |
varchar (8) |
VARCHAR2 (8 CHAR) |
varchar(8) |
true |
1=START, 2=JOB, 3=JP, 4=GROUP, 5=Script, 6=FT, 7=Event, 8=Call Operator, 9=END |
AJPP_Object |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
true |
object name |
AJPP_ErlstStTime |
varchar (10) |
VARCHAR2 (10 CHAR) |
varchar(10) |
true |
Earliest start time |
AJPP_LtstStTime |
varchar (10) |
VARCHAR2 (10 CHAR) |
varchar(10) |
true |
Latest start time |
AJPP_LtstEndTime |
varchar (10) |
VARCHAR2 (10 CHAR) |
varchar(10) |
true |
Latest end time |
AJPP_WElse |
char (1) |
CHAR (1 CHAR) |
char(1) |
true |
WHEN ... ELSE S=SKIP, H=HALT, A=ABEND, X=Block + Abort Signal |
AJPP_WCType |
char (1) |
CHAR (1 CHAR) |
char(1) |
true |
WHEN condition type: space = AND, O=OR |
AJPP_CCType |
char (1) |
CHAR (1 CHAR) |
char(1) |
true |
CALE condition type: 2=CALE EQ, 3=CALE NE, 1 =CALE AND, 4=CALE Ext. |
AJPP_StartTime |
datetime |
DATE |
timestamp |
true |
start time |
AJPP_EndTime |
datetime |
DATE |
timestamp |
true |
end time |
AJPP_PreCnt |
smallint |
NUMBER(38,0) |
smallint |
true |
number of internal predexessors (AJPPA) of this AJPP |
AJPP_Row |
smallint |
NUMBER(38,0) |
smallint |
true |
y-coordinate for jobplan graphic |
AJPP_Col |
smallint |
NUMBER(38,0) |
smallint |
true |
x-coordinate for jobplan graphic |
AJPP_MsgNr |
int |
NUMBER(38,0) |
int |
true |
return code |
AJPP_MsgInsert |
varchar (1024) |
VARCHAR2 (1024 CHAR) |
varchar(1024) |
true |
message insert to the message number |
AJPP_RetCode |
int |
NUMBER(38,0) |
int |
true |
return code |
AJPP_Restart |
smallint |
NUMBER(38,0) |
smallint |
true |
was this a restarted activation? |
AJPP_RefNr |
int |
NUMBER(38,0) |
int |
true |
reference job number |
AJPP_WhenExecute |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
true |
Call-Operator for HALT |
AJPP_Active |
smallint |
NUMBER(38,0) |
smallint |
true |
bitmask: bit 1= active/inactiv, bit 2: hold/normal |
AJPP_RWhen |
varchar (30) |
VARCHAR2 (30 CHAR) |
varchar(30) |
true |
Result: standard result |
AJPP_RExecute |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
true |
Result: Call Operator |
AJPP_RElse |
int |
NUMBER(38,0) |
int |
true |
Result: else 1=halt 2=ignore 3=JP abend |
AJPP_RRepMTimes |
int |
NUMBER(38,0) |
int |
true |
Result: number of maximum repeats |
AJPP_RRepWait |
int |
NUMBER(38,0) |
int |
true |
Result: time between repeats |
AJPP_RRepTimes |
int |
NUMBER(38,0) |
int |
true |
Result: repeat counter |
AJPP_MrtMethod |
int |
NUMBER(38,0) |
int |
true |
Method for Max. Runtime (bitmask) 0=no audit, 1=fix in seconds, 2=fix time, 4=ERT+xx%, 256=Cancel, 512=Start Object, 1024=JP overwrites Object-Settings |
AJPP_Mrt |
int |
NUMBER(38,0) |
int |
true |
Max. runtime in sec. |
AJPP_MrtTime |
char (6) |
CHAR (6 CHAR) |
char(6) |
true |
Max. runtime in time ddhhmm |
AJPP_MrtErt |
smallint |
NUMBER(38,0) |
smallint |
true |
MRT=ERT+xx% |
AJPP_MrtExecute |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
true |
Object to start |
AJPP_TcpATime |
char (6) |
CHAR (6 CHAR) |
char(6) |
true |
AFTER TIME > time |
AJPP_TcpExecute |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
true |
Object to start |
AJPP_Srt |
int |
NUMBER(38,0) |
int |
true |
Min. runtime in sec. |
AJPP_SrtErt |
smallint |
NUMBER(38,0) |
smallint |
true |
SRT=ERT+xx% |
AJPP_TaskIdnr |
int |
NUMBER(38,0) |
int |
true |
AH_IDNR of the task, -1 if there is no task (inactive); Ext: AH_IDNR which satisfied this condition |
AJPP_TcpATimetTZ |
varchar (8) |
VARCHAR2 (8 CHAR) |
varchar(8) |
true |
Timezone for time check point |
AJPP_ErlstStTimeTZ |
varchar (8) |
VARCHAR2 (8 CHAR) |
varchar(8) |
true |
Timezone for erleast start time |
AJPP_LtstTimeTZ |
varchar (8) |
VARCHAR2 (8 CHAR) |
varchar(8) |
true |
Timezone for latest time |
AJPP_MrtTZ |
varchar (8) |
VARCHAR2 (8 CHAR) |
varchar(8) |
true |
Timezone for max. Runtime when a fixed time is used |
AJPP_RExecFlag |
smallint |
NUMBER(38,0) |
smallint |
true |
Result: 0=execute after each unsuccessful execution, 1=execute only after all retries are unsuccessful |
AJPP_LDate |
datetime |
DATE |
timestamp |
true |
Only UC_SYSTEM_SCHEDULE: logical date of this task |
AJPP_PreCntExt |
smallint |
NUMBER(38,0) |
smallint |
true |
number of external predecessors (AJPPA) of this AJPP |
AJPP_ParentObject |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
true |
Only EXTERNAL: Jobplan Name |
AJPP_ExtWhen |
varchar (30) |
VARCHAR2 (30 CHAR) |
varchar(30) |
true |
External Precondition: (Status) |
AJPP_ExtSLTType |
char (1) |
CHAR (1 CHAR) |
char(1) |
true |
External Precondition: Satisfaction Lead Time Type: 0=since last run, 1=after jop plan start, 2=within hh:mm |
AJPP_ExtSLTWithin |
int |
NUMBER(38,0) |
int |
true |
External Precondition: Time in Seconds |
AJPP_ExtElse |
char (1) |
CHAR (1 CHAR) |
char(1) |
true |
External Precondition: Else: 0=Wait, 1=Skip, 2=JP Abend |
AJPP_ExtElseAlarm |
char (1) |
CHAR (1 CHAR) |
char(1) |
true |
External Precondition: Else Alarm: 0=no, 1=yes |
AJPP_ExtTimeout |
int |
NUMBER(38,0) |
int |
true |
External Precondition: Timeout in Seconds |
AJPP_ExtTimeoutE |
char (1) |
CHAR (1 CHAR) |
char(1) |
true |
External Predondition: Timeout Else: 0=Wait, 1=Skip, 2=JP Abend |
AJPP_ExtTimeoutA |
char (1) |
CHAR (1 CHAR) |
char(1) |
true |
External Precondition: Timeout Alarm: 0=no, 1=yes |
AJPP_ExtExecute |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
true |
External Precondition: Alarm Object |
AJPP_TimeoutFlag |
smallint |
NUMBER(38,0) |
smallint |
true |
External Precondition: Timeout On=1, Off=0 |
AJPP_ErlstStTimeT |
datetime |
DATE |
timestamp |
true |
Earliest start time (timestamp) |
AJPP_CmtFlag |
smallint |
NUMBER(38,0) |
smallint |
true |
0/1 flag for menue prompting + flag in runnr# field |
AJPP_Alias |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
true |
Alias Name for ProcessFlow task |
AJPP_ParentAlias |
varchar (200) |
VARCHAR2 (200 CHAR) |
varchar(200) |
true |
Alias Name for ProcessFlow task in ExternalDependencies |
AJPP_ShowPrompt |
smallint |
NUMBER(38,0) |
smallint |
true |
Prompt will be shown, or not |
AJPP_PromptAtGen |
smallint |
NUMBER(38,0) |
smallint |
true |
Prompt at Processflow-Generation or at Job-Generation |
AJPP_BranchType |
smallint |
NUMBER(38,0) |
smallint |
true |
position (branch) of the object in IF: 1=true; 2=false; or FOREACH: 1=LoopPath; 2= EndPath |
AJPP_RunPerPatch |
smallint |
NUMBER(38,0) |
smallint |
true |
Flag, if Task is running per Patch |
AJPP_RollbackFlag |
smallint |
NUMBER(38,0) |
smallint |
true |
Rollback is enabled for task (overrides AH Flag) |
AJPP_RunPerTarget |
smallint |
NUMBER(38,0) |
smallint |
true |
Run per Deployment Target (1=serial, 2=parallel) |
AJPP_SubType |
varchar (8) |
VARCHAR2 (8 CHAR) |
varchar(8) |
true |
OType specific SubType |