Notification Attributes

General Page

Field

Attribute

Value

Access Via:

Title

OBJECT_TITLE

User-defined,
limited to 255 characters.

GET_ATT,
:PUT_ATT (Pre-Process, Process),
predefined variable

Active OH_Inactive   Change Program

Created

USER_CREATED

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

DATE_CREATED

Timestamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT

Modified

USER_MODIFIED

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

DATE_MODIFIED

Timestamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT

MODIFY_COUNT

The number of object modifications.

GET_ATT

Last Executed

 

LAST_USER

The name of the User object,
limited to 200 characters.

GET_ATT,
predefined variable

LAST_DATE

The timestamp in the format "YYYY-MM-DD HH:MM:SS"
If not available: "0000-00-00 00:00:00"

GET_ATT,
predefined variable

USAGE_COUNT

Number of object usages

GET_ATT,
predefined variable

Archive key 1

ARCHIVE_KEY1

User-defined,
limited to 60 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Archive key 2

ARCHIVE_KEY2

User-defined,
limited to 20 characters

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Int. Account

INT_ACCOUNT, INT_ACC, K

User-defined,
limited to 16 characters.

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Sync Page

Field Description Attribute Access Via:
Assigned Sync object SYNC_OBJECT The name of a Sync object,
a maximum of 20 characters must not be exceeded.
Change Program

Attributes Page

Field

Attribute

Value

Access Via:

Queue QUEUE The name of a queue,
limited to 200 characters.
GET_ATT,
:PUT_ATT,
Change Program,
predefined variable
Group GROUP The name of a group,
limited to 200 characters
" " - For an immediate start
GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Int. account

INT_ACCOUNT, INT_ACC, K

User-defined,
limited to 16 characters.

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Priority

CO_PRIORITY

"HIGH" - High priority
"NORMAL" - Normal priority
"LOW" - Low priority

GET_ATT,
:PUT_ATT,
predefined variable

Type

CO_TYPE

"QUESTION" - Request
"MESSAGE" - Message
"ALARM" - Alert
"EMAIL" - Email

GET_ATT,
:PUT_ATT,
predefined variable

SNMP connection

CO_SNMP

"Y" - Activate SNMP connection
"N" - No SNMP connection

GET_ATT,
:PUT_ATT

Send Email

CO_EMAIL

"Y" - Send Email
"N" - No Email

GET_ATT,
:PUT_ATT

Escalation - After ... Min. without response

CO_RISING_TIME

The time in minutes, any value between "1" and "9999"

Reading the attribute creates a 16-figure value with leading zeros.

GET_ATT,
:PUT_ATT,
predefined variable

Escalation - Notification

CO_RISING_NAME

The name of a notification,
limited to 200 characters.

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Automation Engine priority

UC4_PRIORITY

User-defined,
any value between "0" and "255".

GET_ATT,
:PUT_ATT,
predefined variable

TimeZone

TIMEZONE

User-defined,
limited to 8 characters.

GET_ATT,
:PUT_ATT,
Change Program,
predefined variable

Generate at runtime

GEN_AT_RUNTIME

"Y" - Generation at runtime.
"N" - Generation at activation time.

GET_ATT

Tasks running parallel - Max. number

MAX_PARALLEL_TASKS

User-defined,
any value between "0" and "99999"

GET_ATT,
:PUT_ATT,
predefined variable

Tasks running parallel - Else

MAX_PARALLEL_ELSE

"WAIT" - Notification waits until execution is possible.
"ABEND" - Notification terminates.

GET_ATT,
:PUT_ATT

Automatically deactivate when finished

AUTO_DEACT

"NEVER" - Never deactivate automatically.
"ENDED_ERROR_FREE" - In the case of error-free processing, deactivate automatically.
"RESTART_ERROR_FREE" - In the case of an error-free restart, deactivate automatically. 
"ALWAYS" - Always deactivate automatically.

GET_ATT,
:PUT_ATT

Error-free status (for After an error-free restart)

AUTO_DEACT_ERROR_FREE

Task status
limited to 20 characters. See System Return Codes of Executable Objects.

GET_ATT,
:PUT_ATT

Time delay minutes (for Always)

AUTO_DEACT_DELAY

User-defined,
any value between "0" and "99".

GET_ATT,
:PUT_ATT

Notifications Page

Field

Attribute

Value

Access Via:

Subject SUBJECT User-defined,
limited to 255 characters.
GET_ATT,
:PUT_ATT,
predefined variable

Message

 

CALL_TEXT

User-defined

GET_ATT,
:PUT_ATT,
via script variable

Warning! Script variables that are used in texts and should be changed must be used within the first 256 characters. All script variables that are use afterward will not be considered.

Attach reports from Task (RunID) ATTACH_REPORTS_RUNID User-defined,
limited to 32 characters.
GET_ATT,
:PUT_ATT,
predefined variable
Source ATTACH_REPORTS_SOURCE "DB" - Database
"EXTERNAL" - External files
"ALL" - All
GET_ATT,

:PUT_ATT,

via script variable,

predefined variable
Attach a file from Automation Engine (path and file name) ATTACH_FILE User-defined,
limited to 255 characters.
GET_ATT,
:PUT_ATT,
predefined variable

Recipients Section

Field

Attribute

Value

Access Via:

Assigned calendar CALENDAR The name of a calendar,
limited to 200 characters.
:ADD_ATT,
Change Program
Assigned calendar event CALENDAR_KEYWORD The name of a calendar event,
limited to 200 characters.
ADD_ATT,
Change Program

Recipients

RECIPIENT

Recipients can be added to the runtime by using the script element :ADD_ATT and removed with :REMOVE_ATT.

:ADD_ATT,
:REMOVE_ATT

Runtime Page

Field

Attribute

Value

Access Via:

Return code <=

MAX_RETCODE

User-defined,
limited to 11 numbers.

GET_ATT,
:PUT_ATT (Pre-Process, Process)

Note: The status of the file transfer does not affect its return code. If, for any reason, a file transfer fails, the return code is still 0.

Process Page

Field

Attribute

Value

Access Via:

The string in the Process tab of the job should be changed.

SCRIPT

 

Change Program

Notification Attributes Not on a Page

Field

Attribute

Value

Access Via:

Object name

OBJECT_NAME

User-defined,
limited to 200 characters.

Change Program

Automic Web Interface Mode

DCMODUS

"Y" - The Automic Web Interface is active
"N" - No Automic Web Interface is active

GET_ATT

See also: