UC_CLIENT_SETTINGS - Various Client Settings
This predefined client Variable (VARA) object stores client-specific settings. Settings that are specific to clients may control the behavior of the system when the AE starts. They may handle the access control of the authorization system, define maximum life-spans of user passwords, or log the system status. The same settings are shown in the Client object and can be edited there. For more information, see Clients (CLNT).
The VARA object UC_CLIENT_SETTINGS includes the following variables:
-
Indicates the specific characters that you can use in the alias names of Workflow tasks.
-
Default value: -#
-
Restart required: No
-
-
Indicates the Queue object that is used to execute CallAPI scripts.
-
Default value: CLIENT_QUEUE
-
Restart required: No
-
-
Contains the parameters relevant for the Autoforecast function
-
Allowed values: 1 - N
-
Default value: 1
-
Restart required: No
-
-
Contains the following parameters relevant for the Calendar.
-
CALE_LOOK_AHEAD_MAX
-
Default value: 14
-
Allowed values: 0-9999
-
Restart required: No
-
-
CALE_WARN_LEVEL
-
Value: Number of days prior to a calendar's expiration date that triggers an advance warning
-
Default value:No warning given
-
Restart required: Server, see Starting and Ending Server Processes
-
-
CALE_WARN_NOTIFICATION
-
Value: notification that is activated in order to warn in advance that a calendar will expire
-
Default value:Object must be defined or no notification sent
-
Restart required: Server, see Starting and Ending Server Processes
-
-
-
Parameters relevant for Clients
-
CLIENT_PRIORITY
Determines the priority of the Client
-
Allowed values: 200 - 255
-
Default value: 200
-
Restart required: No
-
-
CLIENT_STATUS
Stops and releases automatic processing within a client
-
Allowed values: GO / STOP
-
Default value: STOP
-
Restart required: No
-
-
-
Contains the following deactivation parameters:
-
DEACTIVATION_DELAY_TIME
Deactivation time in minutes
-
Allowed values: Integers only [0,999999]
-
Default value: 0
-
Restart required: No
-
-
DEACT_FAULT_OTHER
Determines what should happen with the tasks that en with FAULT_OTHER status
-
Allowed values: Y (Yes) and N (No)
-
Y (Yes): The deactivation options are not considered. The task itself is deactivated.
-
N (No): The deactivation options are considered.
-
-
Default value: N
-
Restart required: No
-
-
-
Default number of hours in integer form to check for Process Monitoring filters in the Automic Web Interface.
-
Default values: 12 hours
-
Restart required: No
-
-
Refresh interval for viewing tasks in the in the Tasks list and in the monitors (Process Monitoring perspective).
-
Default value: 3 seconds
-
Restart required: No
-
-
Client-wide variable object that contains the following parameters relevant for the Estimated Runtime (ERT) calculation
-
ERT_ADAPTIVE
-
Allowed values: Y and N
-
Y: Activates adaptive ERT calculation
-
N: Deactivates adaptive ERT calculation
-
-
Default value: N
-
Restart required: No
-
-
ERT_ADAPTIVE_DEFAULT_CONTEXT
-
Allowed values:
-
FIXED: Static predefined value
-
AVERAGE: Dynamically retrieved average value
-
LINEAR REGRESSION: Dynamic value, based on linear regression
-
MAXIMUM: Dynamic value, based on the longest actual runtime
-
-
Default value: LINEAR REGRESSION
-
Restart required: No
-
-
ERT_ADAPTIVE_FALLBACK_METHOD
-
Allowed values:
-
FIXED: Static predefined value
-
AVERAGE :Dynamically retrieved average value
-
LINEAR REGRESSION: Dynamic value, based on linear regression
-
MAXIMUM: Dynamic value, based on the longest actual runtime
-
-
Default value: LINEAR REGRESSION
-
Restart required: No
-
-
ERT_CALCULATION
-
Allowed values:
-
BATCH: Deactivates ERT calculation
-
IMMEDIATE: Activates ERT calculation
-
-
Default value: IMMEDIATE
-
Restart required: No
-
-
ERT_CHECK_COUNT
-
Allowed values: Two-digit value between 1 and 25
-
Default value: 20
-
Restart required: No
-
-
ERT_CORR_PERCENT
-
Allowed values: Up to three-digit values
-
Default value: 0
-
Restart required: No
-
-
ERT_FRT
-
Allowed values: Up to three-digit values
-
Default value: 0
-
Restart required: No
-
-
ERT_IGNORE_PERCENT
-
Allowed values: Up to three-digit values
-
Default value: 0
-
Restart required: No
-
-
ERT_METHOD
-
Allowed values:
-
FIXED: Static predefined value
-
AVERAGE: Dynamically determined average
-
LINEAR REGRESSION: Dynamic value based on linear regression
-
MAXIMUM: Dynamic value based on the longest actual runtime
-
ADAPTIVE: Intelligent ERT calculation that considers various factors and runtime parameters
-
-
Default value: LINEAR_REGRESSION
-
Restart required: No
-
-
ERT_MINIMUM_COUNT
-
Allowed values: Two-figure value between 1 and ERT_CHECK_COUNT
-
Default value: 0
-
Restart required: No
-
-
-
Controls the creation of extended reports, see Extended and External Output Reports
-
Allowed values:
-
SCRIPT: Log of the entire script
-
JCL: Log of all job attributes and the generated JCL
-
HOST_JCL: JCL is taken from the target Agent, which is platform-specific
-
OBJECT_ACCESS: Log of access to objects
-
SQL_VAR: Log for access to SQL variables including SQL statement and parameters
Note: Use commas to separate values.
-
-
Default value: Null
No options unless explicitly mentioned.
-
Restart required: No
-
-
Defines the first day of the week
-
Allowed values:
-
1 - Sunday
-
2 - Monday
-
3 - Tuesday
-
4 - Wednesday
-
5 - Thursday
-
6 - Friday
-
7 - Saturday
-
-
Default value: 2
-
Restart required: No
-
-
Specifies which is the first calendar week of a year
-
Allowed values:
-
1 - The week that includes January 1st
-
4 - The first week that includes at least 4 days of the new year
-
7 - The first week that includes 7 days of the new year
-
-
Default value: 4 - The first week that includes at least 4 days of the new year
-
Restart required: No
-
-
Sets the maximum number of tasks that the Automic Web Interface should be displayed in the Process Monitoring perspective
-
Allowed values: 0 - 20000
-
Default value: 5000
-
Restart required: No
-
-
Determines whether authentication via Kerberos Distribution Center is optional or not
-
Description: The authentication via Kerberos is forced for all users of a Client at once. The advantage of this method is that User objects do not have to be changed one by one.
Note: If this parameter is set to N or is not set, KDC_LOGIN_FORCED has no effect.
-
Allowed values: Y and N
-
-
Maximum number of results that are returned by the global search.
-
Allowed values: 1, 50 (Integers only)
-
Default value: 5 rows
-
Restart required: No
For more information, see Global Search.
-
-
Validity Period of Calendar Events Parameters
Client-wide variable object that specifies the number of years considered in dynamic Calendar calculations.
-
NOW_MINUS
-
Allowed values: 1 - 5
-
Default value: 1
-
Restart required: No
-
-
NOW_PLUS
-
Allowed values: 1 - 10
-
Default value: 6
-
Restart required: No
-
-
-
Activates or deactivates object logging and that store the results in the AE DB revision report utility, see AE DB Revision Report
-
Allowed values: Y and N
-
Y: Logging for the revision report is activated
-
N: Logging for the revision report is not activated
-
-
Default value: N
-
Restart required: No
-
-
This key defines which Action Pack structure should be used to export an Action Pack with the Plugin Manager. For more information, see About the Plugin Manager.
-
Allowed values:
-
ALL: The Pack content is exported in both formats: XML, JSON.
-
JSON: The Pack content is exported in JSON format.
-
XML: The Pack content is exported in XML format.
-
-
Default: JSON
-
Restart required: No
-
-
Settings for User passwords
-
PWD_AGE_MAX
-
Allowed values: Integer
-
Default value: Empty
-
Restart required: No
-
-
PWD_ATTEMPTS_MAX
-
Allowed values: Integer
-
Default value: Unlimited
-
Restart required: No
-
-
PWD_CONTAINS_LOWER_CASE
-
Allowed values: Y and N
-
Default value: N
-
Restart required: No
-
-
PWD_CONTAINS_NUMBER
-
Allowed values: Y and N
-
Default value: N
-
Restart required: No
-
-
PWD_CONTAINS_SPECIAL_CHARACTER
-
Allowed values: Y and N
-
Default value: N
-
Restart required: No
-
-
PWD_CONTAINS_UPPER_CASE
-
Allowed values: Y and N
-
Default value: N
-
Restart required: No
-
-
PWD_DEFAULT
Default password for new Users that have been created and configured without a password
-
Default value: pass
-
-
PWD_FORBID_LOGIN
-
Allowed values: Y and N
-
Default value: N
-
Restart required: No
-
-
PWD_GENERATION
-
Allowed values: 1 - 99
-
Default value: 0 (the new password is not compared to any older passwords)
-
Restart required: No
-
-
PWD_LENGTH_MAX
-
Allowed values: 0 - 32
-
Default value: 32
-
Restart required: No
-
-
PWD_LENGTH_MIN
-
Allowed values: 0 - 32
-
Default value: 0
-
Restart required: No
-
-
-
This variable contains the parameters to connect to a public GIT repository to retrieve an updated list of available Packs and versions.
-
Default value: https://github.com/Automic/Index.git
-
Restart required: No
-
-
This variable is used to connect to the repository containing the release notes of the Packs.
-
Default value: https://downloads.automic.com/jart/prj3/depman/interfaces/marketplace/list_packages.jart?to-json=yes
-
Restart required: No
-
-
This variable is used by the Plugin Manager together with the PM_PROXY_PORT variable to access the Internet. For more information, see About the Plugin Manager and PM_PROXY_PORT.
-
Default value: Empty value
-
Restart required: No
-
-
This variable is used by the About the Plugin Manager together with the PM_PROXY_SERVER variable to access the Internet. For more information, see About the Plugin Manager and PM_PROXY_SERVER.
-
Default value: Empty value
-
Restart required: No
-
-
Maximum waiting time for a task that includes PromptSets
-
PROMPT_RESPONSETIME
-
Default value: 0 (= unlimited)
-
Restart required: No
-
-
PROMPT_TIMEOUT
-
Default value: 0 (= unlimited)
-
Restart required: No
-
-
-
Establishes the connection to the remote repository you want to use the Version Control functionality
-
REMOTE_REPOSITORY_URL
SSH URL needed to establish the connection
-
Default value: Null
No URL unless explicitly entered.
-
Restart required: No
-
-
REPOSITORY_SSH_DIR
SSH directory you wish to use when connecting to a remote repository
-
Default value: Null
No dir unless explicitly entered.
-
Restart required: No
-
-
-
Client-wide variable object that contains security parameters relevant for the access trace function of the authorization system
-
SECURITY_AUDIT_FAILURE
-
Allowed values:
-
HOST_ACCESS: All the denied attempts to access a host are logged.
-
LOGON: All the denied login attempts are logged.
-
OBJECT_ACCESS: The denied attempts to access an object are logged.
-
USER_PRIVILEGES: All denied user privileges are logged.
-
-
Default value: Null
No options unless explicitly mentioned.
-
Restart required: No
-
-
SECURITY_AUDIT_SUCCESS
-
Allowed values:
-
HOST_ACCESS: Authorized host accesses are logged
-
LOGON: Authorized logins are logged
-
OBJECT_ACCESS: Authorized object accesses are logged
-
USER_PRIVILEGES: Authorized user privilege uses are logged
-
-
Default value: Null
No options unless explicitly mentioned.
-
Restart required: No
-
-
-
Sets the Agent and the Login object that should be used in SEND_MAIL script functions
-
Format: SEND_MAIL_DEFAULT = <agent object>,<login object>
Note: The Login object used must have an entry with the type MAIL.
If this key is not defined, the email is sent through the Automation Engine.
-
Restart required: No
-
-
Settings for the email connection to the Automation Engine.
-
SMTP_FROM_ADDR
-
Description: Email address of the sender
-
Default value: Null
No entry unless explicitly entered.
-
Restart required: No
-
-
SMTP_LOGIN
-
Description: Name of the Login object that is used to log on to the SMTP server
-
Restart required: No
-
-
SMTP_MAX_ATTACHMENT_SIZE
-
Allowed values: 400 - 50000
-
Default value: 8000
-
Restart required: No
-
-
SMTP_REPLY_TO
-
Description: Email address for the response
-
Restart required: No
-
-
SMTP_SERVER
-
Description: Name of the SMTP server
-
Default value: Null
No entry unless explicitly entered.
-
Restart required: No
-
-
SMTP_TIMEOUT
-
Allowed values: 0 - 999
-
Default value: 20
-
Restart required: No
-
-
-
Influences the behavior of the system after the Automation Engine has started
-
Allowed values:
-
STOP: The Client stops automatic processing after the Automation Engine has been started
-
WAIT x (seconds): The Client suspends automatic processing after the Automation Engine has been started and waits for the specified period of time
-
-
Default value: Automatic processing is immediately active when the Automation Engine has started.
-
Restart required: Server, see Starting and Ending Server Processes.
-
-
Priority of the task processed by the Client. This priority is overruled by the value entered on the Attributes page by developers and object designers when defining an executable object. For more information, see Attributes Page.
-
Allowed values: 1 - 255, where
-
1 = highest priority
-
255 = lowest priority
If no default priority is specified, or if the variable is not available in the Client, the priority of an object is 200.
-
-
Restart required: No
-
-
In combination with the UC_OBJECT_TEMPLATE variable, this parameter determines which templates are provided as basis for the creation of objects.
-
Allowed values: Y and N
-
Y: Users in this Client can see all object types but can only create objects for which they have write access. If a filter has been placed in the authorizations, it is compared with the name of the template when a new object is created. For more information, see User (USER), User Groups (USRG).
-
N: Only the object types that can be created by the particular User are listed in the Add Object dialog.
-
-
Default value: Y
-
Restart required: No
-
-
Specifies what should happen if the values of VARA objects cannot be resolved at runtime when they are used in the attributes of executable objects
-
Allowed values: Y and N
-
Y: An error occurs and processing aborts
-
N: Processing continues. The value is assigned as specified and no replacement takes place (default)
-
-
Default value: N
-
Restart required: No
-
-
Controls the object Version Management functionality
-
VERSION_MANAGEMENT
Determines whether object Version Management is activated or not
-
Allowed values: Y and N
-
Y: Version Management is activated
-
N: Version Management is not activated
-
-
Default value: N
-
Restart required: No
-
-
VERSION_MANAGEMENT_SUFFIX
With Version Management activated, it determines the name of the duplicated (old) object
-
Allowed values: Up to 8 characters. Entries that include more characters are truncated.
-
Default value: OLD
-
Restart required: No
-
-
-
Stores specific information about tasks that are in a waiting status caused by a queue (queue stop or queue limit) in the Automation Engine database
-
Allowed value: QUEUE
This option is deactivated if you specify a different value or no value at all.
-
Restart required: No
-
-
Activates an additional parameter to accelerate the execution of certain Workflows based on their task completion rate
-
Allowed values:
-
NO: No extra parameter is taken into account
-
ABSOLUTE: The task completion rate is taken into account
-
-
Default value: No
-
Restart required: No
-
-
Activates the logging of Job and File Transfer data to facilitate external report analysis
-
Allowed values: Y and N
-
Y: Report data of jobs and file transfers are logged
-
N: Report data of jobs and file transfers are not logged
-
-
Default value: N
-
Restart required: No
-
See also: