Notification Attributes

General Page

Title

OBJECT_TITLE

Value: User-defined

Length: 512 characters

Access through: GET_ATT, :PUT_ATT (Pre-Process, Process), predefined variable

Active

OH_Inactive

Access through: Change Program

Created by

USER_CREATED

Value: Name of the User object

Length: Max. 200 characters

Access through: GET_ATT, predefined variable

DATE_CREATED

Value: Timestamp

Format: YYYY-MM-DD HH:MM:SS. If not available, 0000-00-00 00:00:00

Access through: GET_ATT

Modified by

USER_MODIFIED

Value: Name of the User object

Length: 200 characters

Access through: GET_ATT, predefined variable

DATE_MODIFIED

Value: Timestamp

Format: YYYY-MM-DD HH:MM:SS. If not available, 0000-00-00 00:00:00

Access through: GET_ATT

MODIFY_COUNT

Value: Number of object modifications

Access through :GET_ATT

Last Executed

LAST_USER

Value: Name of the User object

Length: 200 characters

Access through: GET_ATT, predefined variable

LAST_DATE

Value: Timestamp

Format: YYYY-MM-DD HH:MM:SS. If not available, 0000-00-00 00:00:00

Access through: GET_ATT, predefined variable

USAGE_COUNT

Value: Number of object usages

Access through: GET_ATT, predefined variable

Archive Key 1

ARCHIVE_KEY1

Value: User-defined

Length: 512 characters

Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable

Archive Key 2

ARCHIVE_KEY2

Value: User-defined

Length: 512 characters

Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable

Int. Account

INT_ACCOUNT, INT_ACC, K

Value: User-defined

Length:16 characters

Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable

Sync Page

Sync Object

SYNC_OBJECT

Value: Name of the Sync object

Length: 20 characters

Access via: Change Program

Attributes Page

Queue

QUEUE

Value: Name of the Queue

Length: Max. 200 characters

Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable

Job Group

GROUP

Value: Name of the Job Group

Length: Max. 200 characters. Leave it empty for an immediate start.

Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable

Automation Engine Priority

UC4_PRIORITY

Value: User-defined

Length: A value between 0 and 255

Access through: GET_ATT, :PUT_ATT, predefined variable

Time Zone

TIMEZONE

Value: User-defined

Length: Max. 8 characters

Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable

Generate Task at: Runtime

GEN_AT_RUNTIME

Value: Y / N

Access through: GET_ATT

Allow <x> simultaneous executions

MAX_PARALLEL_TASKS

Value: User-defined

Length: A value between 0 and 99999

Access through: GET_ATT, :PUT_ATT, predefined variable

Tasks running simultaneously: Else

MAX_PARALLEL_ELSE

Value: WAIT (wait until execution is possible) / ABEND (Notification terminates)

Access through: GET_ATT, :PUT_ATT

Automatically deactivate when finished

AUTO_DEACT

Value:

  • NEVER
  • ENDED_ERROR_FREE (in case of error-free processing, deactivate automatically)
  • RESTART_ERROR_FREE (in case of an error-free restart, deactivate automatically)
  • ALWAYS

Access through: GET_ATT, :PUT_ATT

Error-free status (for After an error-free restart)

AUTO_DEACT_ERROR_FREE

Value: Task status (System Return Codes of Executable Objects)

Length: Max. 20 characters

Access through: GET_ATT, :PUT_ATT

Time delay minutes (for Always)

AUTO_DEACT_DELAY

Value: User-defined

Length: A value between 0 and 99

Access through: GET_ATT, :PUT_ATT

Notification Page

Recipients

RECIPIENT

Value: User-defined

Access through: :ADD_ATT, :REMOVE_ATT

Assigned Calendar

CALENDAR

Value: Name of the Calendar

Length: Max. 200 characters

Access through: :ADD_ATT, Change Program

Assigned Calendar Event

CALENDAR KEYWORD

Value: Name of a Calendar Event

Length: Max. 200 characters

Access through: :ADD_ATT, Change Program

Subject

SUBJECT

Value: User-defined

Length: Max. 255 characters

Access through: GET_ATT, :PUT_ATT, predefined variable

Message

CALL_TEXT

Value: User-defined

Access through: GET_ATT, :PUT_ATT, script variable

Important! Script variables that are used in texts and should be changed must be used within the first 256 bytes. All script variables that are use afterward will not be considered.

Attach Reports from Task

ATTACH_REPORTS_RUNID

Value: User-defined

Length: Max. 32 characters

Access through: GET_ATT, :PUT_ATT, predefined variable

Source

ATTACH_REPORTS_SOURCE

Value:

  • DB
  • EXTERNAL
  • ALL

Access through: GET_ATT, :PUT_ATT, script variable, predefined variable

Attach file from the Automation Engine

ATTACH_FILE

Value: User-defined

Length: Max. 255 characters

Access through: GET_ATT, :PUT_ATT, predefined variable

Priority

CO_PRIORITY

Value:

  • HIGH
  • NORMAL
  • LOW

Access through: GET_ATT, :PUT_ATT, predefined variable

Type

CO_TYPE

Value:

  • QUESTION
  • MESSAGE
  • ALARM
  • EMAIL

Access through: GET_ATT, :PUT_ATT, predefined variable

SNMP Connection

CO_SNMP

Value: Y / N

Access through: GET_ATT, :PUT_ATT

Send Additional E-mail

CO_EMAIL

Value: Y / N

Access through: GET_ATT, :PUT_ATT

Escalate when No Response

CO_RISING_TIME

Value: Time in minutes

Length: A value between 1 and 9999

Access through: GET_ATT, :PUT_ATT, predefined variable

Notification for Escalation

CO_RISING_NAME

Value: Name of the Notification object

Length: Max. 200 characters

Access through: GET_ATT, :PUT_ATT, Change Program, predefined variable

Runtime Page

Return code <=

MAX_RETCODE

Value: User-defined

Length: 10 characters

Access via: GET_ATT, :PUT_ATT (Pre-Process, Process)

Note: The status of the file transfer does not affect its return code. If, for any reason, a file transfer fails, the return code is still 0.

Process Page

Code on the Process Page

SCRIPT

Changes the code on the Process page

Access through: Change Program

Notification Attributes Not on a Page

Object Name

OBJECT_NAME

Value: User-defined

Length: Max. 200 characters

Access through: Change Program

AWI Mode

DCMODUS

Value: Y / N

Access through: GET_ATT

See also: