Synchronization allows the automatic exchange of data between UVC, UVMS and DUAS.
Variable / Label |
Description |
|
---|---|---|
DUAS v6 to UVMS synchronization cycle OWLS_SYNCHRONIZATION_TIMER |
D |
(in seconds) Cycle of the DUAS heartbeat sent to UVMS. The default cycle is 30 seconds. |
DUAS v6 to UVMS data synchronization cycle OWLS_DATA_SYNCHRONIZATION_TIMER |
D |
(in seconds) DUAS V6 Nodes are synchronized by UVMS: nodes list, alerting rule definitions and security. The default period is 180 seconds (3 minutes). |
Number of synchronizations that can be processed simultaneously OWLS_NB_CONCURRENT_SYNCHRONIZATION |
S |
Maximum number of synchronizations that UVMS can handle simultaneously. If the set limit is reached and a synchronization request is sent, it will be refused. The requested synchronization will occur during the next heartbeat. The default limit is 5. |
UVC to UVMS node status synchronization cycle for DUAS v6 (seconds). Minimal value is 40 seconds OWLS_UVMS_UVC_NODE_STATUS_TIMER |
D |
(in seconds) Set period to refresh the node list. The default set period is 300 seconds (5 minutes). |