Properties can be assigned to each particular task of a Schedule which as a result, can influence their execution. Detailed description about the tabs and the fields/control elements are found in the User Guide. This document serves to explain the particular settings and possible effects. The order in which the different settings are checked is significant.

The following table describes the logical checking order in writing, the Schedule-Logic Diagram gives details in pictures.

Checking Order

Description

Tab

 

Repeated checks during schedule execution

 

Periodic turnaround

In the Attributes of the Schedule, the time span of a period and the specific time for the periodic turnaround can be set. Within a period, tasks are started once.

Attribute

Checking before the start of a task

 

Start time

Point in time at which the task should start.

Start time
   
Start of Period + n days The start of a Schedule whose period has been defined for several days can be postponed if the task is not to be started at the day the period starts.
This is especially important when the Schedule's period has been defined so that the period turnaround is not 12:00pm.
Start time
   

Active

If a task is part of a Schedule but should not be executed, you can set it inactive. It obtains the status ENDED_INACTIVE in this case.

Start time

 

 

Calendar

It is also possible to have a task only executed on particular days. These days can be specified in calendar keywords. If the defined calendar condition does not apply, the task ends with the status ENDED_INACTIVE.

Calendar

Checking during task execution

 

Maximum runtime

A task's runtime can be monitored during the execution of the task, thereby enabling reaction to exceeded maximum runtimes. The task can be canceled or ended and/or another task be executed.

Runtime

Checking at the end of a task

 

Minimum runtime

At the end of task execution, it can be checked if the specified minimum runtime was kept. If not, the same settings can be defined as with monitoring the maximum runtime.

Runtime

 

 

OK status

You can also react to the end status of a task. Tasks can be re-activated and/or any task can be started when the specified status is not met.

The Result tab is not considered if a task obtains the status ENDED_INACTIVE.

Result