Some settings that are stored in the variables can differ from client to client. They regulate the system's behavior when a Automation EngineDiese Komponente steuert ein Automation Engine-System. Besteht aus verschiedenen Serverprozessen. starts, or the authorization system's access control management, they determine the maximum life-span of user passwords, or log the system status.
The same settings are also available in the Client object and can be edited here.
Key |
Value |
Restart required |
Description |
---|---|---|---|
ALIAS_SPECIAL_CHARACTERS |
The indication of specific characters that are allowed to be used in the alias names of workflow tasks. Default value: -# Blanks are ignored. |
No |
The alias name of workflow tasks which can be set in the properties (General tab) is limited to specific characters. To allow characters in the alias names that are usually not available (such as "-"), you can make use of this setting. All the characters that should be allowed must be entered in a row, blanks will be ignored. The order of the individual characters is irrelevant. For example: To allow the characters "-", ":" and "+", you must specify the value in the format -:+. |
API_QUEUE |
The QueueObjekttyp in der Automation Engine. Legt die maximale Anzahl parallel laufender Aufgaben, deren Prioritäten und somit die Reihenfolge von auszuführenden Objekten fest. object that is used to execute CallAPIProgrammierschnittstelle, die entweder direkt oder aus einem anderen Programm aufgerufen werden kann, und ein Script im Automation Engine-System ausführt. scripts. Default value: "CLIENT_QUEUE" |
No | In the Automation Engine, all tasks start in a Queue object. This also includes the execution of CallAPI scripts. By default, the Client Queue (CLIENT_QUEUE) is used for CallAPIs. This key can be used to specify a particular Queue object. |
ARA_WS_INT |
Full URL (including protocol and port) of an Automic Release Automation"Automic Release Automation (ARA) ist eine End-to-end-Lösung für die Definition, Koordinierung, Planung von Freigabe-Prozessen und deren Automatisierung. Dies enthält auch die automatische Durchführung von Anwendungs-Deployments auf großen Serverumgebungen. [Früher ""Application Release Automation"", ""Release Manager"" und ""Deployment Manager"" genannt.]" instance. |
No | Full URL of an Automic Release AutomationName der AWI-Perspektive zur Kontrolle der Automic Release Automation.
(ARA) instance that contains both port and protocol (such as https). For example: http://devhost01.test.spoc.global:80/ARA
This setting is required if ARA workflows should be started via the Automation Engine. |
AUTO_FORECAST_DAYS |
The number of days that are included in the AutoForecast calculation. Default value: "1" |
No |
The AutoForecast creates forecast data for activities that run in ScheduleStartet in periodischen Abständen aktivierbare Objekte. Auch ein eigener Objekttyp in der Automation Engine. objects and Event objects. Depending on the active Schedule and Event objects in the client, a forecast will be created for these objects for a previously defined number of days. |
AUTO_FORECAST_PREFIX |
The beginning of the names of forecasts that are created by the AutoForecast. |
No |
The AutoForecast creates forecast data for activities that run in Schedule objects and Event objects. A prefix needs to be defined for these specific Forecast data so that they can be distinguished from individually-created Forecasts. The whole Forecast name consists of a prefix, the object's name, a date and must not exceed 200 characters. |
CALE_LOOK_AHEAD_MAX |
The maximum number of days that is considered for calculating the next valid date based on calendar conditions. Allowed values: "0 - 9999" |
No |
The maximum number of days that is considered when you calculate the next valid date using the script element CALE_LOOK_AHEAD can be specified in this variable on a client-wide basis. The default value is "14". Keep this value low if you specify individual values in order to avoid performance losses. |
CALE_WARN_NOTIFICATION |
The notification that is activated if the advance expiration warning occurs. |
Server |
When the Automation Engine starts and when a new day begins, the validity dates of all calendars are checked whether they expire within the defined number of days. The specified notification starts for each calendar whose validity date expires. The name of the calendar can be read in the script using the READ buffer as shown below: :READ &UC_CAUSE_NAME,, No alert is sent for Calendar objects of the system client 0000, because you cannot activate objects in this client. |
CALE_WARN_LEVEL |
The number of days prior to a calendar's expiration date that triggers an advance warning. |
Server |
|
CLIENT_PRIORITY |
The priority of the client. Allowed values: "200" - "255" |
No |
You can specify a priority of AE's internal processing for each client. This includes that you can reduce the priority of a non-productive client compared to a productive client. The default setting is 200 |
CLIENT_STATUS |
"GO" - Automatic processing is active. |
UserInterfaceVeralteter Begriff. Ersetzt durch: Automic Web Interface |
You can stop automatic processing and release it within a client. To change the system status, the user requires the relevant privilege in order to do so. Only the system itself can write to the variable. |
DEACT_FAULT_OTHER | Allowed values: "Y" or "N" (default) | No |
"Y[es]": If the tasks end with FAULT_OTHER, the deactivation options will not be considered. The task will be deactivated. "N[o]": If tasks end with FAULT_OTHER, the deactivation options will be considered |
DEACTIVATION_DELAY_TIME |
Allowed values: Integers only. Valid value range: [0,999999] |
No |
Deactivation time in minutes If the following applies, no client-wide delay time will be considered:
For certain executable objects, deactivation options can be set in two ways: By using this key or setting the corresponding value in the UserInterface field of the relevant object. This applies to Workflow"Ermöglicht das Hinzufügen, Anordnen, Verknüpfen, Definition von Eigenschaften und Entfernen von Aufgaben eines Workflows. Ein eigener Objekttyp in der Automation Engine. [Früher ""AblaufPlan"" und ""JobPlan"" gennant.]", Event (Console, Time, Database, File, Time), Notification (Alarm, Mail, Standard), Group, ScriptEigener Objekttyp in der Automation Engine, JobVerarbeitung auf einem Zielsystem. Auch ein eigener Objekttyp in der Automation Engine. and FileTransferÜberträgt Dateien zwischen zwei Rechnern. Auch ein eigener Objekttyp in der Automation Engine.. Please refer to the respective object's parameter descriptions for detailed information. |
DEFAULT_TASKLIST_TIMESPAN |
The default number of hours in integer form to check for Process Monitoring filters in the AWIAutomic-Produkt: Übersichtliche und einfach zu bedienende Weboberfläche, mit welcher der Zugriff auf verschiedene Funktionalitäten der Automation Engine möglich ist.. Default value: 12 hours |
AWI | The default number of hours to check for Process Monitoring filters in the AWI. This setting is overridden when a user selects a time frame. For more information, see Aufgaben filtern. |
DEPLOYMENT_CLIENT |
This activates the client's deployment functionality. Allowed values: "Y" and "N" (default value) "Y" - This activates the deployment functionalities. |
UserInterface | If the client should be used for the Release Manager, you can use this setting in order to activate its deployment functions.
Note that you cannot use the system client 0000 as a deployment client. When you activate this setting (Y), the DeploymentDas Deployment einer einzelnen Applikationsrevision in eine Umgebung innerhalb einer einzelnen Aktivität. tab becomes available in workflows and the General tab, which is available in the properties of workflow tasks, includes the option "Run per Patch" . |
EH_KICK_INTERVAL |
The refresh interval that can be specified for the task view in the Activity Window and monitors. Default value: 3 seconds |
No |
If the properties of a task have changed (for example, start, status, end), the UserInterface receives a message from the Server and the Activity Window and monitor view can be refreshed. You can specify the interval in which messages should be sent to the UserInterface in this key. In doing so, messages are sent in blocks which has positive effects on the performance of your system. No message is sent to the UserInterface if tasks do not change during an interval. |
ERT_ADAPTIVE |
Activation/deactivation of adaptive ERT calculation for the entire client. Permitted values: "Y" (default value) or "N" "Y" - Adaptive ERT calculation is active. |
No |
Settings for the adaptive calculation of the expected runtime (ERT). The adaptive calculation can be activated/deactivated for the entire client using the ERT_ADAPTIVE setting. If the adaptive calculation is deactivated, the tasks that the dynamic ERT method "Adaptive" was defined for ( "Runtime" tab) use the alternative method (ERT_ADAPTIVE_FALLBACK_METHOD). The setting ERT_ADAPTIVE_FALLBACK_METHOD defines the alternative ERT method to be used if either the JWP is not available (Java-based work process, takes over the adaptive ERT calculation), or if the overall calculation has been deactivated (ERT_ADAPTIVE="N"). With ERT_ADAPTIVE_DEFAULT_CONTEXT, you can define factors to be taken into account in the adaptive ERT calculation. You can also specify any object attributes; these must be separated by semicolons. The following factors are taken into account by default:
|
ERT_ADAPTIVE_DEFAULT_CONTEXT |
Information which should be taken into account in the adaptive ERT calculation. You can also specify object attributes; these must be separated by semicolons (;) . Default value: "PARENT_ALIAS;HOST;FT_DST_HOST;FT_SRC_HOST;START_TIME" |
No | |
ERT_ADAPTIVE_FALLBACK_METHOD |
Alternative method for calculating the ERT if adaptive calculation is not possible. Permitted values: "FIXED," "MAXIMUM," "AVERAGE," "LINEAR_REGRESSION" (default value) "FIXED" - Static predefined value |
No | |
ERT_METHOD |
The method to evaluate the estimated runtime (ERT). Allowed values: FIXED, MAXIMUM, AVERAGE, LINEAR_REGRESSION "FIXED" - Static predefined value. Default value: "LINEAR_REGRESSION" |
No |
By deactivating the estimated runtime (ERT) calculation, you can improve the performance of the Automation Engine. If it is deactivated (ERT_CALCULATION/BATCH), you can determine it subsequently for all objects in the database. Use the utility AE DB LoadDas Dienstprogramm DB Load lädt Daten zu unterschiedlichsten Zwecken in die Automation Engine-Datenbank. in order to load the file UC_UPD_ESTIMATE_ERT.TXT. The duration for calculating the expected runtime depends on the number of objects that is involved. The file UC_UPD_ESTIMATE_ERT.TXT contains a line at its end that calls the ERT calculation function. If you specify a client, ERT calculation takes place in this client, otherwise the whole system is included in the calculation. For example: ESTIMATE_ERT 1000 All other validity keys that start with "ERT_" form the default values for calculating the expected runtime (ERT). You can adjust them in the Runtime tab of each object if needed. |
ERT_FRT |
The fixed value for the estimated runtime in seconds. Three-digit value, default: "0" |
No |
By deactivating the estimated runtime (ERT) calculation, you can improve the performance of the Automation Engine. If it is deactivated (ERT_CALCULATION/BATCH), you can determine it subsequently for all objects in the database. Use the utility AE DB Load in order to load the file UC_UPD_ESTIMATE_ERT.TXT. The duration for calculating the expected runtime depends on the number of objects that is involved. The file UC_UPD_ESTIMATE_ERT.TXT contains a line at its end that calls the ERT calculation function. If you specify a client, ERT calculation takes place in this client, otherwise the whole system is included in the calculation. For example: ESTIMATE_ERT 1000 All other validity keys that start with "ERT_" form the default values for calculating the expected runtime (ERT). You can adjust them in the Runtime tab of each object if needed. |
ERT_CHECK_COUNT |
The number of calculated runs. Two-digit value between "1" and "25", default: "20" |
No |
By deactivating the estimated runtime (ERT) calculation, you can improve the performance of the Automation Engine. If it is deactivated (ERT_CALCULATION/BATCH), you can determine it subsequently for all objects in the database. Use the utility AE DB Load in order to load the file UC_UPD_ESTIMATE_ERT.TXT. The duration for calculating the expected runtime depends on the number of objects that is involved. The file UC_UPD_ESTIMATE_ERT.TXT contains a line at its end that calls the ERT calculation function. If you specify a client, ERT calculation takes place in this client, otherwise the whole system is included in the calculation. For example: ESTIMATE_ERT 1000 All other validity keys that start with "ERT_" form the default values for calculating the expected runtime (ERT). You can adjust them in the Runtime tab of each object if needed. |
ERT_CORR_PERCENT |
The positive correction value in percent. Three-digit value, default: "0" |
No |
|
ERT_IGNORE_PERCENT |
The deviation in percent. Three-digit value, default: "0" |
No |
|
ERT_MINIMUM_COUNT |
The minimum number of runs that should be counted for deviation. Two-figure value between "1" and "ERT_CHECK_COUNT", default value: "0" |
No |
|
ERT_CALCULATION |
The determination of the estimated runtime (ERT) by the Automation Engine. Allowed value: BATCH, IMMEDIATE |
No |
|
EXT_REPORTS |
Creates extended task reports. Allowed values: SCRIPT, JCL, HOST_JCL, OBJECT_ACCESS separated by commas. |
No |
You can use this entry in order to specify whether extended reports should be created in addition to standard reports, and which ones. |
FIRST_DAY_OF_WEEK |
The starting day of the week. Allowed values: 1 - 7 "1" - Sunday |
No |
The key FIRST_WEEK_METHOD can be used to define the first calendar week of a new year. By default, the week that includes at least 4 days of a new year is used as the first calendar week. You can also determine the starting day of a week using the entry FIRST_DAY_OF_WEEK (default: Monday). Note that the definitions that are made for the first calendar week influence the results of the script function WEEK_NR which retrieves the calendar week. |
FIRST_WEEK_METHOD |
The definition of the week that is regarded the first calendar week of a year. Allowed values: 1, 4, 7 "1" - The week that includes January 1st. |
CP and WP processes |
|
JOBP_SAVE_INCOMPLETE |
This is the setting for saving workflows. Allowed values: YES, NO or ASK (default) "YES" - The workflow will always be saved. |
UserInterface |
The tasks of a workflow must be linked with lines in order to have them executed in the required order. You can define a predecessor and a successor for each task. You can set storage properties using the entry JOBP_SAVE_INCOMPLETE if some lines are missing. In this case, you can specify that the workflow should be stored (YES) or not (NO), or that it should only be stored after a request (ASK). |
KDC_LOGIN_FORCED |
Forces authentication via Kerberos Distribution Center. (optional) Allowed values: "Y[es]" or "N[o]" |
The authentication via Kerberos is forced for all users of a client at once. If this parameter is set to "N" or is not set, the KDC_LOGIN_FORCED has no effect. |
|
MAX_SEARCH_RESULTS |
Allowed values: Integers only. Valid value range: [1,50] Default value: 10 rows |
AWI | Sets the maximum number of results to return from the AWI Search drop down. |
MAX_USER_INTERFACE |
The maximum number of UserInterfaces that can be logged on at the same time. Allowed values: "1" to max. license count |
No |
For each client, you can specify the maximum number of UserInterfaces that can be connected to the AE system at the same time. If there is no entry, the system uses the value that is defined in the license. |
NOW_MINUS |
The number of years that is considered in dynamic calendar calculation. Allowed values: "1" to "5" |
No |
It is not required to specify a validity period if you create a calendar keyword. The days are automatically calculated on the basis of the determined date intervals. You can use these two keys to specify the number of years that should be calculated to the past and to the future. |
NOW_PLUS |
The number of years that is considered in dynamic calendar calculation. Allowed values: "1" to"10" |
No |
|
OBJECT_AUDIT |
The logging for the revision report. Allowed values: "Y" and "N" (default value) "Y" - Logging for the revision report is made. |
No |
This setting can be used to activate object logging and store the results in Revision Reports. |
PROMPT_RESPONSETIME |
The time in minutes that the system waits for a task's PromptSet dialog to be confirmed. Default value: 0 (= unlimited) |
No |
These settings define the maximum waiting time for a task that includes PromptSets. Depending on the particular situation, the task aborts if this time is exceeded.
The task aborts if the graphical interface is closed although the PromptSet dialog is still open. |
PROMPT_TIMEOUT |
The time in minutes that the system waits for a user to log on in order to display a PromptSet dialog. Default value: 0 (= unlimited) |
No | |
PWD_AGE_MAX |
The life span of the user passwords in days. |
No |
Settings for user passwords: PWD_AGE_MAX PWD_ATTEMPTS_MAX PWD_DEFAULT PWD_GENERATION All other keys that start with "PWD" define the criteria that a user password must meet. If no value is specified for the above settings, the system searches for a default value in the variable UC_SYSTEM_SETTINGS. It uses the fixed default value if it does not include these PWD keys. |
PWD_ATTEMPTS_MAX |
The number of invalid login attempts. |
No |
|
PWD_CONTAINS_LOWER_CASE |
You can use this key to force the use of lowercase letters in user passwords. Allowed values: "Y" and "N" (default value) |
No |
|
PWD_CONTAINS_NUMBER |
You can use this key to force the use of numbers in user passwords. Allowed values: "Y" and "N" (default value) |
No |
|
PWD_CONTAINS_SPECIAL_CHARACTER |
You can use this key to force the use of special characters in user passwords. Allowed values: "Y" and "N" (default value) |
No |
|
PWD_CONTAINS_UPPER_CASE |
You can use this key to force the use of uppercase letters in user passwords. Allowed values: "Y" and "N" (default value) |
No |
|
PWD_DEFAULT | Specifies the default password for new users defined without a password. | No | |
PWD_FORBID_LOGIN |
You can use this key to forbid user names in user passwords. Allowed values: "Y" and "N" (default value) |
No |
|
PWD_GENERATION |
The number of the last n passwords that must not be used again. Allowed values: "1" - "99" "0" signals that the password is not checked against older passwords |
No |
|
PWD_LENGTH_MAX |
The maximum length of user passwords. Allowed values: "0" - "32" |
No |
|
PWD_LENGTH_MIN |
The minimum length of user passwords. Allowed values: "0" - "32" |
No |
|
SEARCH_SCRIPT_FOR_USAGE |
The search for object use in script. Allowed values: "Y", "L" and "N" (default value) "Y" - Search for objects used in scripts (with regular expressions). |
No |
When deleting, renaming or manually searching the use of an object, AE checks if this object is used in other objects as well (for example, in Schedule objects). If so, you can have a list of all these objects displayed. With the specification of the key SEARCH_SCRIPT_FOR_USAGE and the values "Y" and "L", objects that are used in scripts (for example, ACTIVATE_UC_OBJECT) are included in the search. There are different search types: "Y" - The searched string is handled as a word that is enclosed in delimiters such as blanks, left and right parentheses, equals, commas, single quotations, double quotations, end of lines and script ends. For example: Searching for MM only lists results in which this term is enclosed in the listed delimiters.
Underscores are not delimiters. Searching for MM is not successful if you search for _MM_. Note that this search specification is only supported for the MS SQL Server and Oracle version 10g and beyond. Searching by using the option "Y" is more complex and takes longer. "L" - The searched string must be somewhere in the script as otherwise, it is not displayed as a search result. For example: Searching for MM lists results in which this term is included as a whole or partially.
"L" search result are limited to 1000 entries for performance reasons. |
SECURITY_AUDIT_FAILURE |
The authorization system's access control management. "HOST_ACCESS" - All the denied attempts to access a host will be logged. |
No |
The authorization system's access trace function can be defined for each individual client. You can log authorized and/or denied accesses in the categories login, privilege, host access and object access. Single assignments to variable values must be separated by commas. Specify the variable values exactly as described (case sensitive). Single assignments to values are not case sensitive. The access trace function can be reviewed in the System Overview (provided that the required privileges are assigned). Each access results in a security message that informs about the access time, user, access category, host and the actual access. HostRechner, Zielsystem. information is only available if the user is logged on to the UserInterface. Usually, you cannot retrieve host information for tasks that are activated at runtime. If an unknown user makes an attempt to log on to the system, the access denial is logged in client 0000 provided that the access trace function is activated in the variable of client 0000. |
SECURITY_AUDIT_SUCCESS |
The authorization system's access control management. "HOST_ACCESS" - Authorized host accesses will be logged. |
No |
|
SEND_MAIL_DEFAULT |
Key for setting the parameters Agent and LoginAnmeldedaten für Zielsysteme. Auch ein eigener Objekttyp in der Automation Engine. used in SEND_MAIL script functions client-wide. Format: SEND_MAIL_DEFAULT = <agent object>,<login object> |
No |
(optional) This key sets the default values for the agent to be used to send emails and the Login object containing the desired login data for sending emails and attachments. If the parameters Agent and Login are specified in individual SEND_MAIL script functions anywhere throughout the client, those script statement values will be overridden by this setting. |
SMTP_FROM_ADDR | The sender's email address. | No | These settings are part of the Automation Engine's E-mail connection. Using the Automation Engine's Email connection requires the keys SMTP_SERVER and SMTP_FROM_ADDR to be specified. All other settings are optional. |
SMTP_LOGIN |
The name of the Login object that is used to log on to the SMTP Server. |
No | |
SMTP_MAX_ATTACHMENT_SIZE |
The maximum size (in bytes) for the report file that is sent via email. Default value: "8000" In the Notification page of the Notification object, you can enter the RunID"Kurzform für ""laufende Nummer"". Hierbei handelt es sich genauer um eine Zahl, welche die Durchführung einer Aufgabe eindeutig kennzeichnet. Die RunID kann zwischen 7 und 10 Stellen aufweisen. Sie wird von der Komponente Automation Engine vergeben." of a task whose reports should be included in the message. The setting SMTP_MAX_ATTACHMENT_SIZE limits the report-file sizes. When the report file exceeds the maximum value,only the allowed size is read and sent. The file end includes the following note: "Truncated through SMTP_MAX_ATTACHMENT_SIZE limit". This limitation does not affect files that are sent via email. |
No | |
SMTP_REPLY_TO | The email address for the response. | No | |
SMTP_SERVER | The name of the SMTP Server. | No | |
SMTP_TIMEOUT |
The maximum time in seconds that the system waits for an SMTP Server to respond. Allowed values: "0" - "999" |
No | |
STARTUP_ACTION |
"STOP" - The system stops after the Automation Engine has started. |
Server |
By using the entry STARTUP_ACTION in the scope "Freely selected", you can influence the behavior of the system after the Automation Engine has started. The client can either stop automatic processing when the Automation Engine starts or suspend it specified period of time. By default, automatic processing is immediately active when the Automation Engine has started. Note that the parameter SystemStop=YES in the Automation Engine's INI file overrides the settings that have been made in STARTUP_ACTION. |
TASK_PRIORITY |
The priority of tasks. Allowed values: "1" - "255" |
No |
1 stands for the highest, 255 for the lowest priority. If 0 is selected for executable objects in the Attributes tab, the priority that is defined for the client in this entry is used. If no default priority is specified, or the variable is not available in the client, the priority is 200 Note that 0 is the highest possible task priority. It can only be specified here. |
TEMPLATE_SHOW_ALL |
This key affects the list of object types that is shown when objects are created. Allowed values: "Y" (default) and "N" "Y" - The selection dialog shows all object types. |
No |
The content of the selection dialog that is shown while an object is created depends on the following factors:
If value "N" has been specified, only the object types that can be created by the particular user (for example, the user has a "write" privilege) are listed. If you specify "Y", the users can see all the object types but can only create objects for which they have write access. If a filter has been placed in the authorizations , this filter is compared to the name of the template when a new object is created. |
VARA_ERROR_ON_REPLACEMENT |
Here you can specify the required behavior if VariableSpeichert oder ermittelt Werte dynamisch zur Laufzeit. Auch ein eigener Objekttyp in der Automation Engine. objects cannot be found whose value should be used to replace placeholders in attributes at runtime. Allowed values: "Y" (default value) and "N" |
No |
In AE, you can insert values of Variable objects in the attributes of executable objects at runtime. As a placeholder, specify the variable name enclosed in { } brackets as and optionally the key and the column. Notation: The placeholder is replaced by the corresponding value when the task is generated. The value of the result column (in dynamic variables) or the first Value column (in static variables) of the first entry (Key) is used if neither a column nor a key have been specified. The setting VARA_ERROR_ON_REPLACEMENTcan be used in order to determine whether the task should be canceled if the specified variable cannot be found. If "N" is used (system settings) and the Variable object is not available, the attribute value including the invalid placeholder are assumed. |
VERSION_MANAGEMENT |
"Y" - The version control of objects is activated |
No |
The entry VERSION_MANAGEMENT can be used you determine whether the Version ManagementManagement ist der Funktionsbereich des Service Orchestrator, in dem die Verwaltung von Service Level Agreements (SLAs) durchgeführt wird. In diesem Bereich werden SLA-Definitionen erstellt, bearbeitet und gelöscht. Außerdem dient dieser Bereich auch der Verwaltung Ihrer Geschäftseinheiten. of objects should be activated. If so, the entry VERSION_MANAGEMENT_SUFFIX is also important. It is limited to 8 characters and is inserted in the name part of the object that has been duplicated for the Version Management. Entries that include more characters are truncated. Note that the same naming conventions apply for suffixes as for objects. Allowed are the characters: A-Z, 0-9, $, @, _, -, . If you use German Umlauts or do not enter a suffix, the default value "OLD" is used. |
VERSION_MANAGEMENT_SUFFIX |
The part of the name that is inserted in objects that are created in the sequel of a Version Management. Default value: "OLD" |
No |
|
WAIT_STATE_RECORDING |
Stores specific information about tasks that are in a waiting status because of a queue in the AE database. Allowed values: This option is deactivated when you specify a different value or no value (=default value). |
No |
This setting is only relevant when you want to monitor the time slot of tasks relating to queues using the Automic product Predictive Analytics and / or Process AnalyticsEigenes Automic-Produkt. Graphisches Analysewerkzeug: Stellt Statistik-, Aktivitäten- und Prognose-Daten pro Mandant eines Automation Engine-Systems in einem Balken-Diagramm dar und ermöglicht die Berechung des kritischen Pfades. [Früher "ClearView", "Graphical Workload Analyzer" sowie "JobMonitoringStudio (JMS)" genannt.]. When you set the value "QUEUE", the details of all tasks that are in a waiting status because of a queue stop or a queue limit will be logged in the AE database. |
WF_COMPLETION_ACCELERATION |
Setting for completion acceleration of Workflows, which have the highest amount of already completed tasks. Allowed values: "ABSOLUTE"- Tasks in Workflow structures with the highest amount of already completed tasks will be preferred in waiting states . |
No |
The execution order of tasks in waiting states such as 'Waiting for SYNC / .. Queue slot/ ...resource / ...end of parallel task /... is determined by two environmental conditions: With this key set to value "ABSOLUTE" an additional measure will be added, which prefers tasks in running workflows, depending on the absolute amount of already completed tasks in the parent workflow structure. |
XRO_REPORTS |
Allowed values: "Y" and "N" (default value) "Y" - ReportBericht, der nähere Informationen über die Durchführung einer Aufgabe oder einer Komponente enthält. data of jobs and file transfers are logged. |
No |
This key permits the activation of a particular logging that facilitates external report analyses of jobs and file transfers. |